This is the answer:
Probable Cause
This error message
almost always indicate an upper PCA problem when they are consistently
displayed. Failures causing this error message to be displayed are rare.
Corrective Action
If the error message is
consistently displayed when the unit is powered up, the upper PCA should
be replaced. It is possible to see this message displayed
intermittently due to external causes. If the units A.C. input
significantly dips during the power up test sequence the test could fail
resulting in this message being displayed. Treadmills operating on
non-dedicated A.C. circuits may see this message displayed on an
intermittent basis.