Precor EFX 546i Elliptical Version 4 Logo
luis alberto herreragarro Posted on Sep 06, 2013
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

En la pantalla se marca error 40 y la rampa no sube ni baja

1 Answer

Sportsmith LLC

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Precor Master 920 Answers
  • Posted on May 14, 2014
Sportsmith LLC
Precor Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Apr 23, 2014
Answers
920
Questions
0
Helped
514817
Points
111994

Precor Error 40, No Lift Motion Detected Probable Cause 1. Blown lift fuse in lower PCA.
2. Lift motor is physically jammed and not able to move.
3. Bad lower PCA.
4. Bad lift capacitor.
5. Bad lift motor winding.
6. Bad interconnect cable between upper and lower PCA.
7. Bad upper PCA.
Corrective Action

  1. Check the lift fuse from the lower PCA. Using an ohmmeter, the fuse should measure 1 ohm or less. If the reading is significantly high, replace the fuse. If the fuse is open, refer to steps 3 and 4 before continuing.
  2. Disconnect the lift motor from the ramp (elliptical) or lift platform (treadmill). If the lift nut or lift tube is jammed against the motor housing, turn the lift tube or lift nut away from the motor housing. If the lift was jammed, refer to step 3 before continuing. Calibrate the lift motor per the proper procedure for the unit being serviced and reattach the lift motor to the ramp (elliptical) or lift platform (treadmill). NOTICE: You must find and repair the cause for the jammed lift. Only re-calibrating the lift motor will not solve the problem.
  3. One of two modes can cause the lower PCA to fail. The lift switch could fail in an operated condition. If this happens the lift will move (either up or down) as soon as the unit powers up. The usual result is that the lift will be physically jammed as explained above, and probably also being cause for the lift fuse to blow. The lift switch could also fail in an open condition. If this happened, the lift would not operate in one direction. If either of these conditions occur the lower PCA needs replaced.
  4. Most units have the lift capacitor mounted inside the lift motor, and others use external lift capacitors. This information applies to units with the external lift capacitors. If the lift capacitor is shorted the lift fuse blows. Check the capacitor for a short using an ohm meter. Disconnect the capacitor from the lift motor and test. A good capacitor reads in the millions of ohms. Replace the capacitor if the reading is significantly low. Capacitor can also fail in the open condition which would result with the lift motor trying to run but not having normal power. Test the capacitor by measuring AC voltage across it. A good capacitor will read AC peak voltage while an open capacitor reads AC RMS voltage.
  5. When a lift motor winding is bad the lift will not operate in one or both directions depending upon the exact fault in the motor. Check the lift motor winding with an ohm meter. AC lift motors have a split winding (3 wires) and DC lift motors will have a single winding. Both windings must be checked on an AC lift motor. Normal winding readings could vary anywhere between 1 and 60 ohms, depending on the lift motor being tested. See the proper service manual for the motor being tested.
  6. Test unit with a known good interconnect cable. Replace the interconnect cable if necessary.
  7. Test unit with a known good upper PCA. Replace the lower PCA if necessary.

Precor Error Code 40

1 Related Answer

Jose Pino

  • 563 Answers
  • Posted on Dec 07, 2010

SOURCE: CUANDO LA PRENDO SE QUEDA

Lamento el problema con su Precor EFX 546i Elliptical. Al momento que se apaga le aparece algun error? Por favor indique el mensaje o el codigo que aparezca en la pantalla.

Por lo comun, las fallas relacionadas a este equipo similares al problema que tiene es causado por el motor, sin embargo, se requiere el codigo de error para diagnosticar exactamente el problema.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Tengo una ford explore 96 cuando la prendo y la pongo en Drive se me apaga mas se siente como acelera y baja el aceleramiento y sube y baja..

Puede ser el "control de aire de ralent?" motor paso a paso (v?lvula IAC).
It may be the "idle air control" stepper motor (IAC valve).
0helpful
1answer

La presion de aceite de mi jeep grand cheroke 1999 6 cil es de repente se bajo por completo y no me sube la aguja ni a la mitad,,

Chequea los niveles de aceite
Chequea si tienes fuga
chequea el trompo de aceite a lo mejor se ha da?ado
si estan bien los niveles de aceite reemplaza el trompo de aceite.
si persiste es ya el motor.necesita reparacion
0helpful
1answer

La presion de aceite de mi jeep grand cheroke 1999 6 cil es de repente se bajo por completo estando en movimiento y no me sube la aguja ni a la mitad a que se debera esto?

type your question- put in a file -go to a translate site and push translate to english-for some reason I can't do this from my end-I have tried and this system will not let me do it-cheers Denny
12helpful
9answers

Tengo un p9000t pero al iniciaqr DVD, TV o simplemente encenderlo aparesce una imagen que dice warning pleasa stop wacht video player en momentos trasmite el canal y el video pero posterior presenta...

Hola buen dia, mira tengo un stereo con pantalla marca planet audio, modelo P9762T. El probleme es que no funciona el touch y el control igual se descompuso, y no encuentro ni el control ni kien me lo arregle del toach, ayuda x favor saben kien lo puede arreglar y en cuanto saldria o ya de minimo el control. Gracias de antemano y saludos
0helpful
1answer

Mi isuzu rodeo se apaga luego de estar encendido por tiempo.me dicen que esta mal sincronizada.como se sincroniza? les agradecere que me den una respuesta.

tengo una izuzu rodeo 1999 motor 2.2 el problema que presenta son;me marca error dela egr y ya se la cambie, en el tablero me marca 2000rpm pero el scaner dice que tiene 780rpm, las revoluciones se normalizan cuando el clima baja como a 22grados celcius, se me quedaron encendido el ventilador de enfriamiento tuve que ponerles relay con la ignicion, no gasta refrigerante de motor pero le cambie los bulbos de temperatura y la falla persiste,el indicador de combustible se sube y se baja y es nuevo con todo y la bomba, alguien me puede ayudar nadie le encuentra el problema
0helpful
1answer

Mi reproductor MP3 RCA HT103 no logro accesar a el en ninguna computadora. si prende pero no tengo acceso a ningina de sus funciones ni en reproductor ni en la copmputadora, solo se pernde la pantalla y...

Si es la primera vez que usas el reproductor, es posible que este vacio.
Trate de hacer esto:
- connectalo a la computadora usando el connector USB. Espera que Windoes te diga que ha hecho una buena conneccion.
- Cunado esto esta hecho, puedes ver el reproductor en tu computadora como un disco nuevo.
- Copia un par de canciones en formato MP3 a heste nuevo disco (no hagas un folder nuevo)
- Desconecta el reproductor de la computadora (usa el eject USB drive)
- Ensaya de tocar las canciones que copiaste en el reproductor.

Ojala que esto funcione.
0helpful
1answer

Mi control se desconfiguro y no encuentro la solucion al problema

MI CONTROL LG MKJ61841701 SE DESCONFIGURO Y AHORA SOLO TIENE FUNCIONES BASICAS PRENDE Y APAGA CAMBIA CANAL Y SUBE Y BAJA VOLUMEN PERO NO PUEDO ACTIVAR NADA MAS NI MENU NI HORARIO NI ENERGY SAVE NI NINGUNA FUNCION EXTRA. NECESITO AYUDA PARA RECONFIGURARLO. ALGUIEN QUE ME EXPLIQUE QUE HACER. YA HABLE A LG Y ME DICEN QUE COMPRE UNO NUEVO.
3helpful
2answers

Pasword pass

Lo que necesitas hacer es, cuando la unidad te pida el codigo,con el control remoto apuntalo asia la pantalla y forma la palabra KCAR con los numeros 55222277 o aveces es 552222777 dependiendo del control remoto que estes usando.
No vas a ver ningun cambio,ni ninguna letra en la pantalla mientras estes poniendo los numeros con el control hasta que pongas el ultimo numero requerido,la unidad se pondra en STANDBY y listo.
Si cometes algun erreor presiona el boton de reset en la unidad y trata de nuevo del pricipio.
hasme saber si trabajo
GRACIAS
Not finding what you are looking for?

1,395 views

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Sportsmith LLC
Sportsmith LLC

Level 3 Expert

920 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...