Have GWL15 ran diagnostice and lights 2,4,5,6,7 light up tech sheet missing what does this mean?
Your Error code is 94
81. - 95. (0101xxxx) Phase 2 to 3 - Display/ Motor Control
Module. See Fault Code 106
106. (01101010) Phase 2 to 3 and 5 - Display to Motor
Control Module Communications Errors
(Phase 6 IW Also)
These faults are reported when the Display Module detects an error in
the communications between the Display Module and the Motor
Control Module.
Phase 2 to 3
Primary Source: Display Module.
Action: Replace Display Module.
Secondary Source: Motor Control Module.
Action: Replace Motor Control Module. If the new
Motor Control Module corrects the fault, refit the
original Display Module.
Phase 5
Primary Source: Pump
Action: Measure resistance of pump. If resistance is
less than 33 ohms, replace pump.
Secondary Source: Display Module.
Action: Replace Display Module.
Tertiary Source: Motor Control Module.
Action: Replace Motor Control Module. If the new
Motor Control Module corrects the fault, refit the
original Display Module.
SOURCE: GWL15 Tech Sheet
sorry buthtere should be one located under the main console, remove the 2 screws from the back and flip it foward, if not give f&p a calll, they will help you out