My range clicks when I touch the door, it sounds like relays clicking. Would that indicate that it is the EDC that needs replacing, I had origanally thought it was the EOC?
Thanks
Version 1 of your unit F7 error code.
F7
Lock
motor relay watchdog circuit is active when it should be
off
Microprocessor
checking the operation of the EDC lock, relay failed. Replace
EDC.
This does not mean that this is the problem but it is where I would start. EDC is less than a fouth the cost of the EOC.
Please take the time to rate this solution
Thanks,
clarkco
1,190 views
Usually answered in minutes!
×