2. Failed fuser lamp(s).
Check continuity of the three upper fuser lamps L2, L3 and L4. Check the operation of the three upper fuser lamps in the Service Mode by following the steps below. Replace failed fuser lamp (p/n A03U M31E 12 for bizhub PRO C5500/C5501/C6500/C6500P/C6501/C6501P/C65hc and p/n A1DU M31E 00 for bizhub PRESS C6000/C7000/C7000P/C70hc/bizhub PRO C6000L).
a. Press Utility/Counter.
b. Press "Stop 00" "Stop 01" to access Service Mode.
c. Press State Confirmation.
d. Press I/O Check Mode.
e. Enter code 45 using the numeric keys.
f. Press Access to enter multi mode 11 (L2).
g. Press the START key. Verify the lamp comes ON.
h. Press the STOP key.
i. Press "C" key to enter another multi mode.
j. Repeat steps 6 through 8 for multi mode 12 (L3) and 14 (L5).
×