Ecn or Ec Message
Ecn or Ec Message
If
the Ecn or Ec Message is Alternating with the Water Temperature on the
Display, the Spa is Operating in the Economy Heating Mode.
If the
Ecn or Ec Message is ON Solid (Not Flashing) on the Display, the Spa is
Operating in the Economy Heating Mode, but there is No current water
temperature because the Spa is between Filter Cycles.
Ecn or Ec is Alternating with Temp:
The Spa is Operating in the "Economy" (Ecn or Ec) Heating Mode.
The
Water Temperature is Sampled Only during Programmed Filter Cycles. The
Heater will Only operate and Heat up to Set Temperature during the
Filter Cycles. The Water Temperature will probably drop Below Set
Temperature between Filter Cycles. Other Heating Modes are Standard,
Standard in Economy, and Sleep Modes.
Ecn or Ec is ON Solid (Not Flashing):
The Current Water Temperature is "Unknown" (- - - or - -) while in Economy or Sleep Mode.
Between
Filter Cycles, while in the Economy or Sleep Heating Modes, the Pump
has not turned ON and the Last Water Temperature is not Current. To
read the Current Water Temperature, either Change to Standard Heating
Mode or turn On the Heating Related Pump, and wait at least 2 Minutes.