SOURCE: LG STUDIOWORKS 500g - FULL SCREEN NOT GETTING DISPLAYED
It's Loose contact Problem in Vertical section
Pl corrected dry points all over the vertical section.
SOURCE: My studioworks 500G monitor LED blinking with twise colour(Green and Amber)and no display.
1. LOT problem.
2. Horizontal transistor bad.
3. Dry points in neck board, horizontal section.
4. transformer output capacitors problem.
5. IRF 630 ( lot supply fet )
SOURCE: diagram for supply
yes the diagram is in book of G.T. hardware engineering college jaypur in rajasthan india the books are available in metro citi and authorised suppliers only in that book not only diagram but troubleshooting mathods are also given
SOURCE: LG Studioworks model (500G)CRT Monitor flickers most of the time
lg 500g studioworks green color
SOURCE: LG STUDIOWORKS 500G monitor dead ?
your irf 630 is not original purchase it from proper LG authorised service centre it is costly but never become faulty again duplicate mosfet overheats if your green led is on then measure voltage at E.H.T.connect meter at output transister if E.H.T. is producing then meter should show 1 digit if not then 50v will show take care that signal cable should be disconnected if E.H.T. is not producing then check +vcc at horizontal ic it should be 12v. if 12v is not present then check regulator ic 7812 insmps
Testimonial: "thanks a lot :)"
200 views
Usually answered in minutes!
×