I put in a new bag and went to use the vacuum but nothing goes in the bag. It goes behind the bag or infront of the bag. We have the bags that are used for this kind of vacuum. We have tried a different bag to help but nothing works.
Manufacturers and Exporters of all kinds of eco-friendly bags including cotton promotional bags, tote bags, canvas bags, shopping bags etc. from India. http://www.t-traxx.com/blog/tag/travel-tote-bags-manufacturers-in-india
Sounds to me that the tube the bag connect to is broke or as got hole in it.
SOURCE: Won't start.
There is a reset button at the back of the powerhead. The user manual can be downloaded from the electrolux website, although I didn't find it very useful. There was some info on how to change the powerhead drive belt.
SOURCE: vacuum shuts off
if you want to fix this problem gently pry up the air flow control knob and look down at the plastic hose connected below the control valve. insert a small screwdriver and push off the hose from the valve. this disconnects the bag full indicator but will let the vacuum operate normally at full vacuum. you will change the bag when suction gets low. this will save you at least $100 repair bill.
SOURCE: Electrolux Epic 6500SR Full Bag sensor working, Does not Reset properly
The problem was a sticking switch that was not being reset. The vacuum on/off switch mechanism is comprised of two switches. One is the main switch that turns the vacuum on and off. The second is a shut off switch that gets tripped when the full bag sensor is engaged. This second switch is supposed to get reset when you push the on/off switch on the outside of the machine. The full bag shutoff switch was stiff and it, therefore, was taking a couple of presses of the on/off switch to move the shutoff switch back into the running position.
SOURCE: Bag full indication comes on; changed bag; still wont run.
Turn the knob on the top of the vacuum all the way to the right and try it again
SOURCE: my vacuum stops showing "bag full" even after I
This is most probably due to a worn out or clogged Control Valve Assembly.
Detach the hose and see if it runs. If it does, place hand over hole. If it shuts off, CVA is probably the cause. A clogged CVA is generally due to using generic/made-to-fit bags. Genuine bags have "Home Solutions" printed on them.
You can try turning the dial all the way to the large dot, then try to run the vacuum.
If it is the CVA, you'll need to take it to an authorized Aerus Electrolux store and have their service tech repair or replace the part. I recommend a service and clean of the vacuum at the same time. This will extend the life of the vacuum.
Testimonial: "Super reply! Thanks for specific info. I detached the hose and (dang it) had the same problem. The bags are genuine, so it looks like a dealer repair."