Kohler 12 kW Emergency Power System - 12RES-L Logo
Posted on Dec 13, 2008

Kohler lp shuts down

The generator was starting then shutting down after 20 seconds. yesterday the repairman replaced the govenor. today it starts but revs up and down then shuts down after 20 seconds. will continue to run if i hold the throttle steady. if i let go it revs up the down then shuts down. thoughts... will i damage it if i hold the throttle steady to keep it running,
ty
paul

  • 1 more comment 
  • wchorne Jan 17, 2009

    I may have a similar problem. See my post.
    Bill in Salisbury


  • Dan408 Jan 27, 2009

    I have a 11rmy LP, it will start and run from 5 seconds up to 1 minute. I changed the regulator, electronic governor, diodes, filters and plugs. This unit is 9 years with only 150 hrs.

  • Anonymous May 11, 2010

    No matter what you shouldn't hold the governor arm or the throttle to prevent the governor from working, you could do serious damage to the engine in a very short time. I'm not as familiar with your generator as I am others, can you tell me if you have and electronic governor or a mechanical one? Also am I correct in thinking that this is an LP fueled generator? If you've got LP fuel you could very easily be having issues related to fuel pressure and/or delivery volume - this is especially true in cold places :-)

    Hope this helps,
    Carl


×

1 Answer

Anonymous

Level 1:

An expert who has achieved level 1.

  • Contributor 1 Answer
  • Posted on Oct 09, 2009
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Joined: Oct 09, 2009
Answers
1
Questions
0
Helped
974
Points
1

What you need to know is there enough fuel going to the regulator. It should be 7 to 11 inches Water Column. If not your problem may be not enough fuel. That includes when the heater in your house kicks on and what ever gas appliance you may have. Once you verify that you need to figure out if you have the proper pressure coming out of the regular on the inside of the generator. Next I would look at compression of the cylinders. It may need new piston rings.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

Why my generator shuts down and posts a message cc-1 crank cycle

Maybe the start motor is damaged. You can check it first.

Power generation: www.dieselgeneratortech.com
1helpful
1answer

Why does my Kohler 7.3 generator start and runs great for about 5 min. then shuts downRestarts fine but shuts down seconds later. Upon removing rad cap, fluid is seen moving upon warm up. How do I...

change the oil to the correct specification first. As the engine runs the heat changes the viscosity and overheats or trips the oil alert switch. If its over 10 years old change the oil alet magnetic switch
0helpful
1answer

Kohler Generator won't start

If you have a drip leg near generator open that up for a sec and then try it again.
0helpful
1answer
2helpful
1answer

The monitoring system of our Kohler propane generator has sent a "UU" message. What does this mean as it causes the generator to shut down 10 seconds after starting? Also how can this be...

The monitoring system of our Kohler propane generator has sent a "UU" message. What does this mean as it causes the generator to shut down 10 seconds after starting? Also how can this be corrected?
0helpful
1answer

Kohler Model 12RES LP gas generator starts normally but immediately shuts down with over-voltage alarm. Control panel replaced.

Sounds like a short in one of the windings to me. Can you verify that the engine rpm is not exceeding specs? If you can modify the engine speed Id say slow it down and see what the voltage read is.
1helpful
3answers

I have a Kohler 12RESM1 propane generator with oc/uu code

U need to make sure that the relay driving ur auto start stay closed all thru the crank cycle.
Not finding what you are looking for?

984 views

Ask a Question

Usually answered in minutes!

Top Kohler Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66820 Answers

Are you a Kohler Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...