Freezer is about 6 years old and kicks on for about 5 seconds and then shuts off repeats every 2-3 minutes any ideas? model # 253 20402000
SOURCE: Kenmore Upright Freezer Model 253-9280810
is it possible the door has not been closed at some point?
If so they can build up with ice in the evaporator which the defrost system cannot handle....Try a manual defrost.
Depending on where the unit is installed high ambient temperature can drop the internal temp enough to set the alarm off though they will still freeze sufficiently
SOURCE: Freezer runs constantly
not necessarily, is it maintaining temp? all food staying frozen? especially ice creams if stored in there. most newer freezers displace the heat generated while cooling the food through copper lines running through sides of unit, helps to cut down on air temp differences between the inside (0 degrees) and outside temp to prevent moisture and possible condensation causing premature rusting of unit
SOURCE: Kenmore Upright Freezer compressor running 6 seconds every minute
Usually the compressor runs pretty warm anyway. However if you think it's too hot I would start with the condenser coils located either under the unit or on occasion they are located on the back. The air flow across these coils as well as the airflow around the compressor must be maintained. I forgot to ask if the condenser fan is running. Check and make sure that the Fan is running and the air flow is good. Also, When you transported the unit did you move it standing vertically like it normally stands or did you lay it on its side. If you transported the unit on its side you must wait a minimum of 24 to 48 hours prior to start up or the unit could be ruined permanently. The refrigerant has to be utilized through the compressor as a gas. If the unit is on its side liquid refrigerant could be introduced into the compressor and can cause permanent damage. If this is the case I recommend that you turn the unit off at once and wait the 36 hours for the Refrigerant to settle then try it again. This transportation rule applies for any appliance That uses refrigerant, Air Conditioners etc. These units are not that hard to diagnose. The only other item that is usually a problem is the defrost timer. It is not very expensive and can also cause some of the same symptoms that you are eluding to. The defrost timer allows the freezer to periodically shut down to prevent the buildup of frost or ice on he evaporator coils and on the inside the unit. If it is defective, then the unit will either run all the time and cause the evaporator coils to freeze up or will not allow the compressor to switch on and it will not freeze like it should.
SOURCE: problem with upright freezer not freezing
It sounds like the unit is low on freon or the compressor is going bad. You have several other components that could be affecting this as well. Make sure the coils are free from dust and clean underneath. This is a bit premature for you to have problems now, especially since it is a Sears product.
SOURCE: My kenmore frostless 16 upright freezer alarms
kenmore elite, alarm kept going on and b flashed on and off. I finaly figured out on bottom of freezer there is a battery door open it and change 9v. thats it,
Frigidaire has also jumped into
the market with an adaptive defrost board. The fresh food section light switch
and light bulb must work. To initiate a defrost cycle, open the door and push
the light switch in and out 5 times within 6 seconds. The compressor and fans
should shut off and the defrost heater should come on. Open the door and push
the light switch in and out 5 times within 6 seconds to remove the refrigerator
from the defrost mode and back into a cooling mode.
This product comes equipped with an
Adaptive Defrost Control (ADC). To activate manual defrost, press and hold the
Freezer temperature UP (WARMER) key while pressing the Fresh Food temperature
DOWN (COLDER) key 5 times within 6 seconds. A "d" in the freezer temperature
window and "F" in the refrigerator temperature window will display when the
heater is activated. To deactivate manual defrost, press and hold Freezer
temperature UP (WARMER) key while pressing the Fresh Food temperature DOWN
(COLDER) key 5 times within 6 seconds. "d" and "F" will be displayed until the
defrost cycle is complete. (approx. 8 minutes)