SOURCE: I have a Beverage Air
You'll need to check the back-pressure on the low-side of the system, you have a faulty compressor. If there is a condenser fan motor make sure it is running when the compressor is on.
SOURCE: my mt 12 cooler doesnt blow cold just warm air
thermostat could not be set properly, compressor could not be running, unit could be low on freon. start checking some items and let me know.
SOURCE: bev air cooler
Bill, the main reason I've noticed for higher than normal temps in these boxes is filthy condenser coils (this will affect pressures in your sealed system). Remove the front lower panel and inspect your coils. Use a coil brush or a dust broom to thoroughly clean them up, don't use water. You can also pick up some condenser coil cleaner in a spray can from your local appliance parts store, but it's not necessary (the fumes are strong and may be objectionable to your customers... it gets 'em really clean, though!) After cleaning the coils, allow 24 hours for temps to stabilize. If they don't, here is a site for Beverage-Air, contact your local servicer with you exact model and serial number for pressure specifications. http://www.beverage-air.com/technical.service.html Hope this helps! Let us know, will ya?