Have a Lutron Skylark SF-10P need to wire to existing 3 wires

My customer want to have a dimmer install to control flourescent lights.
He has 2 fixtures with 4-35 watt skinny tubes in each.

I went to a electrical supply house, told them what I had and what I was trying to do. They sold me Lutron Skylark SF-10P.

This is the problem, at the switch plate there are 3 wires, one black, one red and the ground (green). The SF-10P has 5 wires, one black, one red, one yellow, one green and one white.

Would you tell me how to wire this thing?

Thanks

1 Answer

Anonymous

Level 1:

An expert who has achieved level 1.

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 61 Answers
  • Posted on Nov 30, 2008
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Hot-Shot:

An expert who has answered 20 questions.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Nov 27, 2008
Answers
61
Questions
0
Helped
54338
Points
98

You have to have a special ballast on the light to dim fluorescent light fixtures. You also have to have a special dimmer.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer
0helpful
1answer

I'd like to know how to install the dimmer to light switch.

Go to your breaker panel and turn the breaker off that controls the light you want to dim. Remove the screws from the wall plate and switch. Remove the 2 wires from the switch and attach them to the dimmer wires. If there is a 3rd wire it should be green or bare this is the ground wire, do not confuse it with the power wires.
0helpful
1answer

I bought a Hunter fan Model 21778 that uses 2 incandescent candelabra lights. Before installing it I called Hunter support to see if it was okay to use a dimmer switch for these lights (I had already...

They're right, you don't want to control the whole thing with a single incandescent dimmer. First of all, the fan-speed and the lights will all be controlled by the same dimmer setting (dim low, low fan-speed - dim high, high fan-speed) - and the dimmer's not rated to control fans anyway which can result in exactly what they said.

There is a Skylark control, the S2-LFSQ- where half the knob controls the light, the other half controls the fan. The only problem you may (and most likely) have is that in order for that to work, between the electrical box for the dimmer and the fan, there needs to be seaparate wire run for the fan, and a separate wire run for the light so that the dimmer can individual control both.

If that's a problem, I recommend the MA-LFQM-, which includes a module that you install in the ceiling with the fan. The wall switch it comes with speaks to that module, and gives you independent control of the fan and light without having to install new wiring. I have one of those myself, I've installed one in one of my friend's houses, and they work pretty well and then you don't have to worry about what wires you've got in your wall.
0helpful
1answer

I have two black wires in box attached to regular light switch & want to know if I can install a Skylark S-603PG single pole dimmer switch which has one black , one red&white, red and green wires

This is single-pole -or- 3-way dimmer
Manual shows on following link:
http://www.lutron.com/TechnicalDocumentLibrary/0301107A.pdf

1) Manual says: The red/white wire is not used in a single-pole application. Twist a wire
nut over this wire for a single-pole application.
2) Green wire connects to bare ground wire. Or bare ground to bare ground.
3) Connect dimmer-red and dimmer-black to either insulated wire that came off of old switch

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, fixya expert speaks with you over phone while you work on dimmer or any do-it-yourself project.
We are always less expensive than a service call.
0helpful
1answer

How to install

Lutron S2-LFSQ is made to control one ceiling paddle fan & 1 light. Switch will not work on florescent lights.
See manual

To use this product, your fan and light must already be controlled by 2 separate switches.

If you have just one switch that turns on the light & fan together, the S2-LFSQ will not work (without additional wiring).

Okay, you have two switches. One switch turns fan on-and-off. The other switch turns light on-and-off.

Here is wiring diagram from manual: See diagram larger

8263536.jpg

Here's how to wire:
-Before disconnecting wires from existing switches, mark each wire with tape and pen.
-There is one wire that feeds power to both switches > mark this the 'Hot wire' and it connects to Lutron black wire (if you are unsure about this wire, remove switches, separate wires, turn on power and test each wire to bare ground, tape tester leads to wood sticks so hands are away from power, Tester lights up on Hot wire)
-The switch that controls fan > mark this the 'Fan wire' and it will connect to Lutron Yellow wire
-the switch that controls light > mark this the 'light wire' and it will connect to Lutron Red wire
-Lutron Green wire or bare wire connects to bare ground wire.
0helpful
1answer

4 can lights wired to two 3 wire Lutron

The interior flood light bulbs were the new flourescent energy savers. I replaced them with incandescent and it worked with the dimmers.
1helpful
1answer

Replaced existing Lutron skylark low voltage dimmer

You will need to return the 3-way dimmer and get a single pole dimmer, as the Lutron Skylark series is suspectible to failure if connected to a live circuit first, or misconnected at intial installation. As an electrician, I ceased using these dimmers years ago, due to the rash of call-backs by customers and went with Leviton togglers and have had excellent results.

If you purchased it at a 'big box' store, they will accept the return as a defective item, as they have national agreements with their suppliers to accept customer returns. Just tell them it didn't work and you want a store credit, you can then purchase the lower priced single pole dimmer you need and save some money in the process too.

Hope you find this Very Helpful - best regards!
0helpful
1answer

Lutron skylark s-10p 1000w dimmer. why is one

This video from the Lutron site shows the Diva switch but it is the video for the Skylark single pole switch also. It makes no mention of one wire being a larger gauge and does not differentiate which wire connects to line power and which to load. I do not think the wire gauge makes any difference.
Not finding what you are looking for?

445 views

Ask a Question

Usually answered in minutes!

Top AMS Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66936 Answers

Are you an AMS Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...