My amana forced air heater/air conditioner will not start. It clicks a few times and then stops trying to start there is no flame. Thank You for your time. Ed
SOUNDS LIKE THE IGNITOR IS BAD OR NO GAS IS AVAILABLE.THREE ATTEMPTS TO LIGHT AND THE SAFTY SHUTS IT DOWN SO WE KNOW THERE IS A CALL. FORCED DRAFT IS RUNNING,AND AN ATTEMPT TO LIGHT IS OCCURRING. CHECK TO SEE IF 120 VOLTS IS BEING SENT TO THE IGNITOR IF IT IS AND IGNITOR IS NOT GLOWING THEN ITS BAD . R AND R EXACTLY AS FOUND. DONT TOUCH CERAMICS, WEAR COTTON CLEAN GLOVES .YOU ARE PROBABLY GOING TO HAVE TO PAY A PRO CAUSE THE PRTS ARE NOT GOING TO BE SOLD TO A HOME OWNER DUE TO THIS BEING A GAS FURNACE. A PRO WILL FIX , WARRANTY, AND TEST HEAT EXCHANGER, AND BE THERE INSURED IF THERE IS A PROBLEM.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
More likely the pipe sensor is defective (a sensor inside the evaporator ,connected to the thicker gas line).... if it don't send any temperature changes to the control board after 5 minutes , it believes the A/C isn't working and cuts off the whole thing to safeguard the compressor from damage ....
you can remove the acess panel fornthlower front, and the heate and thermostats are located on back wall, check for continuty, in hte thermnaostats and heater
when the coils freeze up , from intake of outside air, when using the heat pump mode, the unit will try to defrost the coils before going back to heat mode. mine did this alot. does it kick back to heat after a few mins? also after 2 years , mine started having issues with the exhaust blower control and would go into warp mode and bang noise.seems like common issues for this unit.whether the amana, or haier version.
This unit goes in steps, 1-- thru--4 Step 1, vent fan blower motor runs & prove thru the air tube, which closes a switch and tells the circuit board to go to step---2 Step 2 lights the glow plug and goes to step 3 automatically, Step 3, opens the gas valve and send in gas thru the long venturi tubes which lights from the glow plug and on the last tube, theres a rod that sticks into the flame, if no flame or not working properly, it will shut down the starting sequences and retry for 4-times and automaticaly lockout till unplug and start over. (whever step it stops at, then thats where your problem is!
Thank you for your time jasond Ill give it a try
×