CAUSE: Failed 1st Image Transfer Pressure/Retraction
Motor (M11) and/or Transfer Belt/Cleaning Unit. SOLUTION: Perform an I/O check on M11 then verify that
the motor and Transfer Belt/Cleaning Unit drive components are not bound up.
Replace M11 (p/n 9314 1100 72) and/or the Transfer Belt/Cleaning Unit (p/n 4049
212) as needed. IMPORTANT: If
the error reoccurs, there is probably an open ICP on PWB-MC (due to a current
overload caused by M11 or a bound Transfer Belt/Cleaning Unit). Replace PWB-MC
(p/n 4036 7811 07).