Hello, does the dryer drum spins? If so, then replace the heating element in your dryer. Look on the back of the dryer, if there is inspection plate about 10"x10". First, unplug your dryer, this is very important to your life. Once the dryer has been unpluged then remove the inspection plate.

Now, if there isn't an inspection plate on the back of your dryer. The the front of the dryer will need to come off. Just leave the dryer door on. Turn the dryer on it side---Remember to unplug your dryer--- On the bottom of the front dryer panel with the door is three or 4 screws just remove these screws. Now, pull the bottom the dryer front panel out about 2" or 3" and pull the front panel down. There is two snap locks that are hooked in the top of dryer cover. Pull the dryer panel out and reach in aroun the door to unplug door switch. I hope this work out for you. GB...stewbison

Posted on Sep 23, 2011

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Why wont my 2001 ford windstar blow out of vents ? only on defrost?


Air Flow Control
Air flow control is accomplished in the following manner:
  • Primary control is through the function selector knob , mounted on the heater function selector switch, which is part of the heater control .
  • The function selector knob has the following positions: OFF, PANEL, PANEL/FLOOR, FLOOR, FLOOR/DEFROST and DEFROST.
  • The heater function selector switch combines a vacuum selector valve with an internal electrical switch.
  • The vacuum selector valve directs source vacuum to various vacuum control motors (18A318) . Refer to the System Airflow Schematic and Vacuum Control Charts.
  • An internal single-pole electrical switch is also controlled by the selector. The switch controls the electrical supply to the heater blower motor switch (18578) .
  • The position of the function selector knob determines the manner in which the system will operate.
  • Each position of the function selector knob is detented for positive engagement.
  • You probably have a vacuum leak , Pull heater control panel an check for vacuum . A broke vacuum hose or The vacuum selector valve is bad ! Or check for a vacuum hose in the engine compartment being off somewhere !

Mar 08, 2015 | 2001 Ford Windstar

1 Answer

Heater control valve function


no the heater control valves function is to stop coolant (water) flow through the heater core . there is a cycling switch on the low side a/c line or accumulator drier this cycling is to keep the evaporator from freezing up and it also cycles when system is low on refrigerant .

Jul 23, 2014 | 2000 Oldsmobile Bravada

1 Answer

1997 Ford Taurus front defrost not working


. Air won't blow out of the floor or center vents just defrost ? Do you have manual or automatic climate control ?
Air Flow Control
Air flow control is accomplished in the following manner:
  • Primary control is through the function selector knob mounted on the A/C-heater function selector switch, which is part of the integrated control panel.
  • The function selector knob has the following positions: OFF, MAX A/C, A/C, PANEL, PANEL/FLOOR, FLOOR, FLOOR/DEFROST and DEFROST. The A/C-heater function selector switch combines a vacuum selector valve with an internal electrical switch.
  • The vacuum selector valve directs source vacuum to various vacuum control motors (18A318). Refer to the Vacuum Control Diagram , System Airflow Schematics and Vacuum Control Chart .
  • Two internal, single-pole electrical switches are also controlled by the A/C-heater function selector switch. The combination of these electrical switches controls the electrical supply to the A/C clutch and heater blower motor switch (18578).
  • The position of the function selector knob determines the manner in which the system will operate.
  • Each position of the function selector knob is detented for positive engagement.
  • Vacuum Control Motors The vacuum control motors (18A318):
    • are located on the A/C evaporator housing, A/C recirculation air duct and heater air plenum chamber (18471).
    • direct system airflow to the vehicle interior as determined by the remote climate control module or manual override.
    • The five-passenger seating configuration has an additional vacuum control motor mounted on the heater air plenum chamber to control airflow to the rear seat A/C register (19893).


vacuum control motor-i4bq0ig33y1522pr2d2rrkk3-2-0.gif

Jul 09, 2017 | Ford Cars & Trucks

1 Answer

1984 toyota pu


Are the heater controls cable operated? You would need to look under the dash and see if the cables are still attached and still functioning when heater controls are moved. The cables will attach to doors to direct heat out.

Dec 11, 2013 | Cars & Trucks

1 Answer

Water heater timer


If everything is wired correctly, the timer switching function may be no good.

Nov 11, 2013 | Intermatic WH40 - Water Heater Time Switch...

1 Answer

Hi our heater enduro13 shows locked sign and i dont know how i can fix it. its getting cold and can you please help me.


To deactivate the Lock function press both the Up and Down Temperature buttons simultaneously for 3 seconds. The Lock indicator will go out to show that the Lock function is no longer active. The Lock function can be deactivated at any time in this manner.

Hope this helped you. Please let me know ... Cheers!

Jul 05, 2011 | Rinnai RHFE-1004FA 38,400 BTU Energy Saver...

1 Answer

Control panel not working after "function lock" buttons pressed


MD,

Hit the up and down again and do away with the Function Lock.

Tom

Apr 23, 2009 | Rinnai RHFE-1004FA 38,400 BTU Energy Saver...

1 Answer

I have a 2000 ford E350 van with front and rear air. the front blower motor runs at low speed, The front blower still runs on low even when the knob is set on medium or high. I do not know where the...


it's either the blower motor switch or blower motor resister. Resistor ?Heater Blower Motor Switch Removal Remove the battery (10655) ; refer to Section 414-01 . Remove the battery tray. Remove the screws. Remove the battery tray. Disconnect the heater blower motor switch resistor connector. Remove the heater blower motor switch resistor (18591). Remove the two screws. Remove the heater blower motor switch resistor. ----------------------------------- Switches Removal Disconnect the battery ground cable. Remove the center trim panel; refer to Section 501-12 . Remove the control assembly. Remove the screws. Remove the control assembly. Remove the A/C-heater function selector switch knob. Disconnect the vacuum harness connector. Disconnect the A/C-heater function selector switch connector. Remove the A/C-heater function selector switch. Remove the screw. Remove the A/C-heater function selector switch. Remove the temperature control switch knob. Disconnect the temperature control switch connector. Remove the temperature control switch. Remove the screw. Remove the temperature control switch. Remove the heater blower motor switch knob. Disconnect the heater blower motor switch connector. Remove the heater blower motor switch (18578). Remove the screw. Remove the heater blower motor switch. ----------------------------

Mar 31, 2009 | 2007 Ford E-350 Super Duty Length XLT

1 Answer

Rannai function lock


Have you tryed unlocking it by holding down on the lock button for 5-6 seconds?

Oct 11, 2007 | Rinnai RHFE-1004FA 38,400 BTU Energy Saver...

Not finding what you are looking for?
Dryers Logo

Related Topics:

82 people viewed this question

Ask a Question

Usually answered in minutes!

Top Dryers Experts

Marvin
Marvin

Level 3 Expert

85206 Answers

Brad Brown

Level 3 Expert

18108 Answers

paul
paul

Level 3 Expert

825 Answers

Are you a Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...