20 Most Recent
Precor EFX 5.21s Elliptical Cross-Trainer - Page 5 Questions & Answers
No power on my precor c964i control board
Starting at the outlet, follow power into the machine. If you are getting power past the circuit breaker and in to the power board, chances are your lower board is toast. The only solution is to replace the item with a new or known good used board. The following links will take you to a video on how to use a multimeter to verify power.
Video about Multimeter Testing
I keep getting a speed error message when I start the belt
Replacement Parts for Fitness Exercise Equipment at SPORTSMITH
Precor Error LS, Speed Sensor Signal Missing
Probable Cause
1. Intermittent or open connection of the speed sensor (reed switch) wiring.
2. Reed switch is defective or has intermittent connection.
3. Drive motor brushes are bad.
4. Lower PCA is bad.
Corrective Action
- Inspect the speed sensor (reed switch) wiring for damage or poor connection to the lower PCA. Replace damaged wiring or reset connection as necessary.
- Using an ohm meter, test the reed switch while rotating the drive pulley. The reed switch will close when the magnet passes in front of it.
- Inspect the drive motor brushes and replace if necessary.
- Test unit with a known good lower PCA. Replace lower PCA if necessary.
Precor Error Code LS
Not finding what you are looking for?