Two "cooper wiring devices" "390-6107XX-EG1D" occupancy sensors in a circuit at the top and bottom of a stairway.which are generating huge amounts of noise in the AM radio band. All the time its "O

Remove the two sensors. If they are connected to your lighting on the same circuit you may need to replace then with '3-Way Switches'. Also see this warning: http://www.saferproducts.gov/ViewIncident/1232148
11/23/2013 12:45:03 AM • Cooper Wiring... • Answered on Nov 23, 2013
0answers
0helpful
1answer
0helpful
1answer

I just had some new

if outlets are equipped wit tamper proofing(little white thing inside of holes),yes ,you will need to push them in a little harder then normal- designed so a child can not easily insert anything
6/5/2011 6:01:33 PM • Cooper Wiring... • Answered on Jun 05, 2011
0answers
0helpful
1answer

I want to wire a 250volt 15 amp ac receptical

This one's an easy one. If you're comfortable doing this yourself, great, if not, I'd strongly recommend getting some help with it, though. No need to get injured or killed over this. If you and your friends aren't comfortable working with electricity, be safe and call an electrician. It'll only take him or her about 30 minutes and $70 in materials to do this for you.

First, locate and turn off the breaker feeding that 240V outlet. Put a piece of black tape over it and tell the whole family to make sure noone turns it back on. Take the cover off of the existing outlet and use a voltmeter to verify that it's dead. Now, take the screws out of the outlet so you can pull it out from the wall and disconnect the wires from it. There should be a black wire, a white wire and a bare wire. If not, let me know. Now go to your local Lowes, Home Depot, or other DIY store and pick up a NEMA 5-20R GFCI outlet. It'll look like all of the other outlets in your house, but it will have "extra" sideways slots in the middle of the tall neutral slot. This outlet is designed to handle higher amperage loads and some larger air conditioners will require it. Connect the black wire to the gold-colored screw on one side and the white wire to the silver colored screw on the other side. Connect the green or bare copper ground to the green or silver screw on the top. Put a couple wraps of black tape around the outlet and put it in the wall with the cover.

Now, back to that 2-pole breaker...you'll need to replace it with an inexpensive 15A breaker (to fill an empty slot and prevent someone from putting fingers where they don't belong) and a 20A AFCI breaker. Yeah, they're expensive as heck, but assuming this is in a living space, they're required by code and will help protect your family againsta fire. Make sure to install it as per the instructions it will come with. Assuming this is wired to Romex wire, you'll need to connect the white wire to the neutral bus (the bar full of screws where most of the other white wires are connected) and connect the black wire to the new 20A AFCI breaker.

Now, if you've wired it all correctly, you'll flip the breaker and it won't trip. (If it does, go through your connections and make sure nothing is shorted out. If you still have a problem, play it safe and call an electrician.) Go to the outlet hit the test and reset buttons a few times to make sure if functions correctly and you're good to go.

Hope that helps.
5/24/2009 5:18:57 PM • Cooper Wiring... • Answered on May 24, 2009
0helpful
1answer

Manual for scorpion sl2800 generator

Yes
4/9/2024 2:32:16 AM • Electrical... • Answered on Apr 09, 2024
0helpful
2answers

My conlog meter is showing the rfcon error please what do I do

No connecting to your utilty company in South Africa. Just FYI, we are a North American site and my not always have the answer, in this case we do Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error-cant-do-anything-on-the-gadget-please-help-on-how-to-re/962048393965724/ Quoting from link above: "Conlog Hi Ola-daniels, Please see below steps to assist with RFCON error : * Press the Back arrow on the keypad - this step is to refresh the UIU ( the device) * Type # 75 # - this is to check the signal strength If it does not go back to the normal display *Type # 80 # - this is to refresh the meter Then lastly you can repair the meter and the UIU by # 36 # The above steps will work better if you are outside the house because the meters uses the radio frequency connection The above error will occur in instances of bad weather conditions or if there is load shedding or power failure If the problem persists after trying the above you may contact the municipality or the service provider."

SOLVED: How do I clear up the rf con error on my meter ...

https://www.fixya.com > ... > The
May 7, 2020 - How do I clear up the rf con error on my meter because I want to ... Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error- ... Hi Ola-daniels, Please see below steps to assist with RFCON error : ... shut down the energy alimentation for 2 minute ,but if the defect persist error it show again. SOLVED: Pole meter conlog rf con meter keep on freezing ... Jan. 10, 2017 Meter reading shows rF CON instead of units available - Fixya Jun. 24, 2018 SOLVED: Good day my conlog ip54 elecricity meter showd ... Oct. 6, 2018 SOLVED: Rf con error - Fixya Jun. 20, 2020 More results from www.fixya.com

Please Help With My Conlog Prepaid Meter - Technology ...

https://www.nairaland.com > please-conlog-prepaid-meter
Aug. 6, 2020 - ystar: If the conlog meter is showing rf-Con, it means power supply doesn't reach the meter at all its either Loss of phase from the transformer or a loose contact ... How Do I Load The Activation Token On My Conlog Prepaid ... Mar. 17, 2020 I Need A Technician To Fix This... - Nairaland / General - Nigeria Jul. 22, 2019 I Need Number Codes To Reset Memmcol Prepaid Meter ... Jan. 11, 2019 More results from www.nairaland.com
3/24/2024 3:42:46 AM • Electrical... • Answered on Mar 24, 2024
Not finding what you are looking for?
Cooper Wiring Devices Cooper Decorator Lighted Decorator Switch Logo

3 questions posted

Ask a Question

Usually answered in minutes!

Top Cooper Wiring Devices Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

john h

Level 3 Expert

29494 Answers

Are you a Cooper Wiring Devices Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Cooper Wiring Devices Electrical Supplies

  • Cooper Wiring Devices Electrical Supplies

Most Popular Question

hookup 3way switch from walltoswitchtoa

  • Electrical Supplies
Loading...