Top 20 Jacuzzi Signa 6 Whirlpool JAC-B540... - Page 6 Questions & Answers

0helpful
1answer

I set the temp to 75 then the spa show 108 and set

This sounds to me like one or both of the sensors on your spa may be bad and need replacing. There are two sensors in each hot tub. One for the temperature of the water and a high limit to prevent the water from going over 112 degrees. If one of these is bad then the sensor will not read the correct water temperature. Rod US Parts Center
8/22/2013 1:10:54 AM • Jacuzzi Home • 200 views • 0 helpful votes
0helpful
1answer

Tank takes a long time to fill

check for a clog in the toilet valve supply as the washer can deteriate or the old piping in the house can clog if they are old and made of galvanize pipe or the fill valve is clogged. replace valve and or fill valve in the tank
8/3/2013 5:47:31 PM • Jacuzzi Home • 199 views • 0 helpful votes
0helpful
1answer

Breaker trips on startup

If your circuit breaker is tripping when you turn the pump on it is caused by a bad motor. The motor probably has a short in it causing the breaker to trip,Replace your pump and that should solve your problem with the breaker.There is an outside chance you may have a bad circuit breaker too.US Parts Center
9/2/2013 3:39:51 AM • Jacuzzi Home • 89 views • 0 helpful votes
0helpful
1answer

Onga spa master

What is the nature of your question? Rod US Parts Center
8/14/2013 11:22:42 PM • Jacuzzi Home • 95 views • 0 helpful votes
0helpful
1answer

Power button pushs in and doesn't start

If you press the air button in and it does not turn the pump on you need to check a couple things.
  • Is the circuit breaker on
  • is the hose still attached to the bottom of the air button and the air switch on the pump
  • check the air switch in the motor - it probably needs to be changed.
US Parts Center
8/26/2013 1:53:13 AM • Jacuzzi Home • 60 views • 0 helpful votes
0helpful
1answer

What red light flashing codes

the motor has probably seized from rusted bearings. check pump for problems. possible failure of capacitor for motor.
6/22/2013 11:56:25 PM • Jacuzzi Home • 169 views • 0 helpful votes
2helpful
1answer

How do you replace a jacuzzi air switch

The air switch used in jetted tubs is mounted in the box on the bath pump.Remove the pump from under the tub and take the top of the little box off by removing the two screws holding it in place.Once the screws are removed you may lift the lid off and you will see two wires going to the air switch, one wire coming from the pump power cord and the other from inside the motor.Remove the two wires from the air switch and then remove the air switch from the pump by taking off the nut that holds the air switch in place.Reinstall the air switch by putting the two wires back onto the air switch and put the cover back on the box on the motor.rodus parts center888-521-6183
4/6/2013 4:21:10 PM • Jacuzzi Home • 1,271 views • 2 helpful votes
0helpful
1answer

I CANT TAKE IT A PART TOO CLEAN

What are you taking apart to clean? What is the nature of the cleaning you are trying to do? Rod US Parts Center
8/4/2013 3:58:35 PM • Jacuzzi Home • 49 views • 0 helpful votes
0helpful
1answer

I need a lid for my skimmer

What brand and model of skimmer do you have? Rod US Parts Center
8/14/2013 11:24:38 PM • Jacuzzi Home • 34 views • 0 helpful votes
0helpful
1answer

The panel on my jacuzzi bathtub keeps falling off. Previous owner said something about needing clips.

You will need to get those clips at your local Jacuzzi Whirlpool Dealer or use Velcro to hold each panel in place.RodUS Parts Center888-521-6183
3/4/2013 8:50:30 PM • Jacuzzi Home • 2,153 views • 0 helpful votes
1helpful
1answer

Can I disconnect one of the jets on my Jacuzzi brand jetted tub, so I can use less water and still have a water level above all the remaining jets?

To disconnect one of the jets to get more water flow to the other jets may not be very practical as you will need to remove the tub and cut the plumbing to the jet in question and cap it off.The other solution that you may use is you have adjustable jets is to turn the water off by the face of the jet, clockwise.If your jets are not adjustable then the first solution would be your only option other than purchasing a large horse power bath pump so you would get more water flow.

Rod Kidman

US Parts Center

We locate the "seemingly" impossible...

Ph: 888-521-6183

Fax: 801-417-8027

"Chat Live"

3/30/2013 8:43:00 PM • Jacuzzi Home • 333 views • 1 helpful votes
0helpful
1answer

I have a Jacuzzi whirlpool bath model U640 Espree 536 and it wouldn't shut off. I cut the air line off at the pump and nbow it won't stay on for more than a few seconds. Any ideas?

I assume you hooked the hose back up to the air switch on the motor.There will only be a couple of things to check.Make sure you have a good connection with the air hose to the air switch on the motor. Sounds like maybe the air switch may be bad. The Air Switch is a latching air switch so if is broken then it won't latch when the air button is pushed.Rodwww.uspartscenter.com
1/23/2013 11:22:14 PM • Jacuzzi Home • 1,413 views • 0 helpful votes
0helpful
1answer

Hot tub won't come on

Start at the spa.
  • Do you have voltage coming to the terminal strip in the control box?
  • Is it the correct voltage?
  • Do you have voltage at any point after that?
  • Is there power coming out of the transformer?
these are the starting points to determine if you have a bad circuit board or a bad transformer.RodUS Parts Center888-521-6182
3/27/2013 11:27:02 PM • Jacuzzi Home • 203 views • 0 helpful votes
0helpful
1answer

Hytec Kohler Model LM34520 air jet swtich not working. 4 years old and last use, the push button stopped working. Cannot see connection detail at switch/button end but disconnected at motor and and

The problem you are experiencing tells me that the air switch in the motor most likely the problem. This is a latching air switch that operates when the button on the side of the tub is pushed. The replacement TBS-339 air switch is around $21 Rod US Parts Center
1/6/2013 9:11:19 PM • Jacuzzi Home • 1,501 views • 0 helpful votes
0helpful
1answer

Regarding a 30x60 indoor jetted tub (Jacuzzi). When I push the on/off button, the pump slows down but then a few minutes later starts again on its own when there is no water. Any idea what is going

IF that is the one I recall, the switch is not connected to the tub. When you press the button, it sends air pressure to the switch under the tub to activate it;. You need to check the tubing and the switch
2/22/2013 8:21:08 PM • Jacuzzi Home • 365 views • 0 helpful votes
1helpful
1answer

Circuit braker keep popping

Sounds like the heating element has gone out again. Once you reset the circuit breaker and the tub turns on it will start to circulate the water. This usually runs like this for about 2 mins and then the tub will recognize it is cold and send power to the heater. If the element is back at that point it will blow the circuit breaker.If this circuit breaker pops as soon as you turn it on then you most likely have a bad circuit board.Rodwww.uspartscenter.com
1/30/2013 11:36:24 PM • Jacuzzi Home • 575 views • 1 helpful votes
1helpful
1answer

Hot water is very slow coming out spout. Cold water comes out fine with good pressure..

the anti scald is adjusted too low. its located under/behind the handle. it usually has am allen wrench head. remove the handle and adjust it all the all the way to hot that should fix it. on some models you can remove the entire thing,but on some that will cause the handle turn 360deg because in some models its also the stopping point of the handle. hope this helps
12/11/2012 2:02:56 AM • Jacuzzi Home • 741 views • 1 helpful votes
0helpful
1answer

J315 lights flickering

Check the connections of the light bulb and any connecting wires. Short of this you may have a faulty transformer. Rod US Parts Center
2/11/2013 6:47:22 PM • Jacuzzi Home • 75 views • 0 helpful votes
0helpful
1answer

My jacuzzi motor is not working

When you push the button and the motor does not turn on there a couple of things to check.Is there power to the pump? check the circuit breakerIf there is power to the motor then the air button on the top of the tub may be bad or it could be the air switch inside the motor.RodUS Parts Center521-6183
1/11/2013 6:55:57 PM • Jacuzzi Home • 147 views • 0 helpful votes
0helpful
1answer

I need a new on off switch

What kind of control are we talking about? Is this and Air Button or an Electric button?RodUS Parts Center888-521-6183
2/23/2013 12:47:32 AM • Jacuzzi Home • 41 views • 0 helpful votes
Not finding what you are looking for?
Jacuzzi Signa 6 Whirlpool  JAC-B540... Logo

Popular Tags

22 questions posted

Ask a Question

Usually answered in minutes!

Top Jacuzzi Home Experts

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Gene Lawson

Level 2 Expert

53 Answers

Are you a Jacuzzi Home Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Jacuzzi Home

  • Jacuzzi Home

Most Popular Question

jacuzzi hot tub model j 300 series fl 1

  • Home