Kohler rite temp with diverter.
You could have a restriction in the tub spout or just too much pressure. Diverter only restricts flow to tub spout so any restrictions to the tub spout will cause water to go up to shower head.
5/27/2011 2:28:55 PM •
Kohler...
•
Answered
on May 27, 2011
Low pressure and diverter not
remove the temp handle first decorative handle then brass sleeve under that brass should slide straight out you will see the mixing housing witch is brass cup shape piece about the size of washing powder cap there will be a small black plastic screen there pull out clean and replace then put back together should have good pressure which will fix diverter problem
11/10/2010 1:04:14 AM •
Kohler...
•
Answered
on Nov 10, 2010