20 Most Recent
Coleman Powermate 024 0091CT High Speed Air Sander Questions & Answers
Speed Control Question
When you are finishing the surface of wood, it's vital to maintain control. Work too fast or too slow and you risk ruining your hard work with unsightly scratches
1/2/2009 3:15:37 PM •
Coleman...
•
Answered
on Jan 02, 2009
I have a coleman evcon furnace and it wont work it
One flash mean ignition failure. The sequence is: T-Stats calls for heat, inducer motor comes on, igniter glows orange (look through glass), then gas comes on and burner lights, approximately 1 minute later the indoor blower comes on. If you don't see the glow, most likely the igniter is bad. If you see the glow but no flame, it's a gas problem, supply or defective valve.
Can you get a replacement Evcon PN 7956-319 board
Please see link below:http://www.northamericahvac.com/servlet/the-2287/Coleman-Gas-Furnace-Control/DetailORhttp://www.climatedoctors.com/items/item.aspx?itemid=6802187I have confirmed from a number of sites that the 7956-319 and 7956-319P boards are compatible.Good luck.
I am trying to start
I fixed my 3 blinking issue: I pulled off the small blower motor above the vacuum sensor and spun the fan with my finger. It had resistance at first but then it spun freely. I put everything back together and it ran. I figure next year I may have to buy a new motor, but I made it this year. By the way that fan creates the vacuum to allow the sensor to work. It is a safety thing I figure. If the fan seizes up again the unit will sense it and shut down.