Goldstar DH5010B Dehumidifier - Answered Questions & Fixed issues

0helpful
1answer

Leaks water

The water may be condensation dripping in an area where the catch components are not able to catch it. The largest line that exits the cold coil and ends at the compressor should be insulated without any tubing showing all the way back to the compressor, deficits in the insulation (even small ones) could cause condensation to form and drip.
3/16/2017 12:38:37 PM • Goldstar DH5010B... • Answered on Mar 16, 2017 • 309 views
0helpful
1answer

I need a water bucket

Here is a link to where you can find the water bucket you need.

http://www.appliancefactoryparts.com/search/partinfo.php?partsID=276540&modelsID=&typeName=air%20conditioner


Hope this helps you and thanks for choosing FixYa.
6/26/2013 11:38:24 AM • Goldstar DH5010B... • Answered on Jun 26, 2013 • 126 views
0helpful
1answer

Freezing

Hi,

Here is a tip that I wrote that will help you understand why and what you cando with a dehumidifier that ices up.

Dehumidifier is Freezing up and not working

heatman101
8/15/2011 4:38:51 PM • Goldstar DH5010B... • Answered on Aug 15, 2011 • 78 views
0helpful
1answer

Need a new reservoir.

Cindy, all dehumidifier tanks are plastic. If they weren't they'd rust. If you want to replace it, you're looking for Part # 48380A20052. You can find it at the following link. Just be more careful, removing and reinstalling it.

http://www.appliancefactoryparts.com/search/partinfo.php?partsID=276540&modelsID=&typeName=dehumidifier

Hope this helped you.
7/1/2011 2:54:55 AM • Goldstar DH5010B... • Answered on Jul 01, 2011 • 80 views
0helpful
1answer

Back and coils freezing up

There are 4 basic, but solvable reason for what you described. Before undertaking any of them, Turn the Master ON/OFF Switch to OFF and unplug the unit. Allow the unit to thaw completely.

1. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

2. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

3. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

4. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder
level
in basement applications . Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the defrost sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

Hope this helps you to trouble shoot and solve the problem.
6/30/2011 8:25:58 PM • Goldstar DH5010B... • Answered on Jun 30, 2011 • 228 views
0helpful
1answer

Stopped removing water from the

Hi,
There are many reasons why a dehumidifier willnot work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrongwith their dehumidifier

Dehumidifier is running but no water is in bucket

heatman101
5/11/2011 12:02:20 AM • Goldstar DH5010B... • Answered on May 11, 2011 • 222 views
0helpful
1answer

The back coils are freezing over

Turn down the thermostat
2/19/2011 11:31:54 PM • Goldstar DH5010B... • Answered on Feb 19, 2011 • 73 views
0helpful
1answer

Dehumidifier freezes up

Hi,

Here is a tip that I wrote that will help you understand why and what you cando with a dehumidifier that ices up.

Dehumidifier is Freezing up and not working

heatman101
10/9/2010 4:03:38 AM • Goldstar DH5010B... • Answered on Oct 09, 2010 • 571 views
0helpful
1answer

Same with me

Hi,
Dehumidifiers2_bing.gif freezing up can be causes by a few different problems.
Here is a tip that I wrote to help people with the freezing dehumidifier2_bing.gif problem....

Dehumidifier is Freezing up and not working
http://www.fixya.com/support/r4662033-dehumidifier_freezing_up_not_working

heatman101
7/13/2010 7:30:43 PM • Goldstar DH5010B... • Answered on Jul 13, 2010 • 201 views
0helpful
1answer

Our dehumidifier keeps running without any water

Hi,
Yes it seems that it is toast....just to be sure check out this tip...
There are many reasons for a dehumidifier2_bing.gif to not work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrong with their dehumidifier2_bing.gif.

Dehumidifier is running but no water is in bucket
http://www.fixya.com/support/r4662409-dehumidifier_running_but_no_water_in

heatman101
5/18/2010 2:32:39 AM • Goldstar DH5010B... • Answered on May 18, 2010 • 164 views
0helpful
1answer

Five year old dehumidifier will not keep running.

Hi,
There are many reasons for a dehumidifier2_bing.gif to not work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrong with their dehumidifier2_bing.gif.

Dehumidifier is running but no water is in bucket
http://www.fixya.com/support/r4662409-dehumidifier_running_but_no_water_in

heatman101
5/14/2010 1:06:56 PM • Goldstar DH5010B... • Answered on May 14, 2010 • 174 views
0helpful
1answer

Goldstar Dh5010, evaporator is freezing up on one

Hi,
Here is a tip that I wrote about that problem...

http://www.fixya.com/support/r4662409-dehumidifier_running_but_no_water_in

heatman101
4/30/2010 11:27:30 AM • Goldstar DH5010B... • Answered on Apr 30, 2010 • 253 views
0helpful
1answer

Float broken inside tank

what you can do is that you can go onto appliancefactoryparts.com type in your model number and see if they have it there by your model number. if not i do know that ebay and amazon have them as well... if you have any other questions please feel free to ask us.
9/9/2009 11:36:52 AM • Goldstar DH5010B... • Answered on Sep 09, 2009 • 173 views
0helpful
2answers

Dehumidifier

Most dehumidifiers have a "Frost Guard" mounted on the condensor coil. If frost accumulates on the condensor coil the frost guard turns the compressor off until the frost melts, then comes back on again. For the dehumidifier to work properly, the surrounding (ambient), temperature must be higher than 65 degress. This temperature allows the moisture in the air to condense on the coils and drip into the reservoir without freezing up on the condensor coil. Also, if the humidity is too low, (below 45%), the same condition will occur. So it will help to keep the parameters in mind when you have this issue.

Thank you for your allowing me to advise you on this issue.

Dave E. (Illeagle)
2/11/2009 4:55:10 PM • Goldstar DH5010B... • Answered on Feb 11, 2009 • 955 views
0helpful
2answers

Turns on, won't fill resevoir

check compressor is running
2/11/2009 4:46:44 PM • Goldstar DH5010B... • Answered on Feb 11, 2009 • 537 views
0helpful
1answer

Gold Star 3850A20500F Dehumidifier. I am trying to figure out how do you open the front where the water collects. We tried all and it does not open.

Question edited for clarity.Question moved from Refrigerators to Goldstar Dehumidifier.Just Answer, says it pulls straight out.Check if it was on the Recall list? Melted plastic would stop it coming out. It was listed as a fire hazard.https://www.google.com/search?q=Gold+Star+3850A20500FTrying to find a manual for it, but your 'model' number seems flawed.https://www.google.com/search?q=Gold+Star+3850A20500F+manual..
7/2/2023 11:39:34 PM • Goldstar... • Answered on Jul 02, 2023 • 56 views
0helpful
1answer

Goldstar dh404e coils not cold throw out or reasonable fix

I would just replace it.
10/5/2018 8:12:08 PM • Goldstar... • Answered on Oct 05, 2018 • 330 views
0helpful
1answer

DH304Y5...is this Goldstar dehumidifier that has been recalled?

The DH304Y5 dehumidifier is not subject to any recalls at this time. I hope this helps. Cindy Wells
9/10/2017 11:58:48 PM • Goldstar... • Answered on Sep 10, 2017 • 234 views
0helpful
1answer

Is a gold star dehumidifier supose to be noise

I can't hear YOUR dehumidifier and can't tell if it's out of the ordinary, but dehumidifiers have all the same internal parts as a refrigerator with the addition of a fan to blow air through the coils to keep them from freezing up. They do tend to be a bit noisy.
2/22/2015 7:52:30 AM • Goldstar... • Answered on Feb 22, 2015 • 156 views
0helpful
1answer

Goldstar dehumidifier dh404ey7 starts and runs about 5 mins., then trips house breaker in all different outlets.

any appliance that trips the fuse or breaker should not be tried to use by homeowner this is a fire hazzard as an electric short is a dangerous situation to have in any home , replace unit ! ck with mfg for recalls first and warrentys as well then contact your power company sometimes they give rebates for appliance upgrades but they require old ones back in order to pay u money on them
10/23/2014 2:35:40 AM • Goldstar... • Answered on Oct 23, 2014 • 214 views
Not finding what you are looking for?
Goldstar DH5010B Dehumidifier Logo

31 questions posted

Ask a Question

Usually answered in minutes!

Top Goldstar Dehumidifiers Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66855 Answers

Are you a Goldstar Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...