20 Most Recent
Nor-Lake NLF72-S 3 Door Bottom Mount Reach-In Freezer | 70 Cu. Ft Questions & Answers
I changed the defrost timer
L1 goes to 1-2 on Clock, L2 or Neutral to N on Clock, Defrost heater to 3 on Clock, Defrost Limit/Fan Delay to X on clock
9/3/2022 11:32:29 PM •
Nor-Lake...
•
Answered
on Sep 03, 2022
Having wiring problem freezer works
I have a generic wiring diagram that I use on all my installs that works very well. It is basically the same for most all commercial walk in freezers. Send me a email address and I'll scan and forward what I have.
10/16/2010 10:10:11 AM •
Nor-Lake...
•
Answered
on Oct 16, 2010
My freezer wont stop running
either the cold control thermostat is defective or the rtc overload contactor has welded itself together and cant open and close the power contacts to the unit,un plug the cold control and see if the unit stops then
2/27/2010 8:40:02 PM •
Nor-Lake...
•
Answered
on Feb 27, 2010
Tappan TFC13M0AW1 Chest Freezer. What part should I replace?
Question edited to add maker! All questions need 'make model (what it is) as first three words.
That is an overheating fault. Replace the fluff with no fluff.
Make sure the condenser coils are free of dust and there is good airflow
Or
It is low on refrigerant gas and you need a service tech..
..
2/3/2024 5:25:13 AM •
Freezers
•
Answered
on Feb 03, 2024