Whirlpool GSS30C6EYW 30 cu. ft. Side-by-Side Refrigerator with Tap Tou - Page 5 - Answered Questions & Fixed issues
I have a model ED2CHQXKB05,
What you are describing is the normal sounds it makes when it goes into defrost. The frost melts, and the resulting water will fall onto the heater which then makes your hissing noise. You dont mention that there is a problem, such as not cold or water leaking on your floor, so it sounds like all is working as it should. But you also mention you taped IT ( what is it?) to the wall in a circle.
10/12/2010 4:12:56 PM •
Whirlpool...
•
Answered
on Oct 12, 2010
•
210 views
Hello! I have a
Hi! Yes, it surely is clogged. Dirt build up inside the tube is possible and the only thing that can resolve this is by draining the tube by cleaning. You will need an experience techinician to resolve this for this requires a hands on fixing. It will require a vacuum for freezer and other stuffs for cleaning the freezer. Hope this helps and thank you for using Fixya!
10/12/2010 1:02:43 PM •
Whirlpool...
•
Answered
on Oct 12, 2010
•
81 views
Just open the chest freezer
Go buy some charcoal and call some friends.... Sorry. Transfer as much as possible to neighbors freezers. If that's not possible keep the freezer as full as possible. Solids hold their cold much better than air.
Could be many things. Remove the thermostat control and cross the wires. did it go on? Replace the thermostat.
Take a multi-testor and check for power at the motor/ compressor. If yes- the compressor motor is bad. Probably fatal for the unit. If not- why is there no power? Follow the supply wires back up line until you find power. replace the part that has failed.
Good luck
Spencer
10/7/2010 2:23:39 PM •
Whirlpool...
•
Answered
on Oct 07, 2010
•
99 views
I don't have the model
Well, its good that it is still cooling, however since you cannot adjust the temps, you do still have a problem, and one that may include the unit fails to cool properly.
10/5/2010 4:42:06 AM •
Whirlpool...
•
Answered
on Oct 05, 2010
•
208 views
Fridge freezer stopped making ice digital display
I have seen this a few times on whirlpool refrigerators. There is likely a high voltage board mounted inside a grey or white box mounted next to the compressor. The noise is usually eminating from this box, and replacing the board will solve all of your problems most likely.
10/1/2010 7:41:51 PM •
Whirlpool...
•
Answered
on Oct 01, 2010
•
105 views
The door on our older
chance are that the frost has turned to ice if the unit started to defrost then got cold again.do a full defrost and then try starting from warm....
9/25/2010 6:06:00 PM •
Whirlpool...
•
Answered
on Sep 25, 2010
•
87 views
Water freezing in bottom of
The defrost drain outlet is stopped up and freezing over.
Remove the bottom basket.
Turn the freezer off.
Look in the center of the freezer just below the cooling coils in the bottom of the freezer.
You will see a water drain trough.
It will be full of ice.
Use a hair dryer to thaw the ice and remove it.
The drain will become exposed.
It must be thawed also,so that you can pour water through it and the water goes all the way to the drain pan underneath.
9/19/2010 1:49:25 PM •
Whirlpool...
•
Answered
on Sep 19, 2010
•
287 views
Alarm will not go off
May first guess is that you have not changed the batteries. Second guess send me the model # so I can look up the wiring dia and give it a shot.
9/13/2010 1:35:09 AM •
Whirlpool...
•
Answered
on Sep 13, 2010
•
65 views
We get clicking noises when water is dispensed.
the clicking sound is normal it sounds like valve operating or you may have the water pressure up to hgh for the unit. for your second problem is the fan operating inthe fridge this stops the cold air to transfer from the freezer, also check the operation of the damper this is the flap the controls the amount of air into the fridge this is uasualy controled by a by metalic thermostat or motor. thirdly which mostly common is the defrost heater is not working signs are frozer evaperator in freezer and air duct the checks are defrost timer, heater element terminatinion thermostat and someunits have thermofuses goodluck
8/28/2010 12:24:08 PM •
Whirlpool...
•
Answered
on Aug 28, 2010
•
224 views
Tripping electricity
HI, The reason for the over-pull is due to the unstable conditions located at the main PCB that controls this affected unit. The voltage is not stable, due to the damage located at the PCB(circuit instabilities). Just to be safe, have your local electrician inspect the breaker box for shorts and damage to the appropriate circuit block. If the electrician confirms that the breaker is in good condition; replace the main control board(PCB) that is mounted near the compressor or behind the rear access panel.
7/21/2010 11:25:36 PM •
Whirlpool...
•
Answered
on Jul 21, 2010
•
329 views
Alarm on freezer keeps gooing off
low on gas or defrost mode failure....if the element become frozen then the air will not circulate around freezer compartment properly....check the defrost element or timer.
7/20/2010 7:16:19 PM •
Whirlpool...
•
Answered
on Jul 20, 2010
•
234 views
The tube feeding the ice making machine is iced
The water inlet valve on the back of unit opens when the ice maker needs water. If the valve doesn't seal good because of sediment or wear it will continue to drip and when the water reaches the ice maker supply tube it will freeze blocking the fill tube.. You can take the water line off the valve and watch to see if it drips.
6/4/2010 2:21:19 PM •
Whirlpool...
•
Answered
on Jun 04, 2010
•
141 views
Not finding what you are looking for?