Protech Rheem/62-24084-82-1PK - Integrated Furnace Control Board IFC Questions & Answers
Protech 62-24084-02 troubleshooting
62-24084-02 LED CODES
POWER LED - GREEN
ON - Normal
OFF - No power to board
OK LED - GREEN
One Blink - One hour retry delay
Two Blinks - Pressure switch failure (remains open)
Three Blinks - Limit switch fault
Four Blinks - Pressure switch failure (remains closed)
Five Blinks - Twinning fault
FLAME LED - YELLOW
ON - Good flame
Rapid Blink - Flame present with gas valve de-energizing
Slow Blink - Marginal flame
1/19/2014 6:13:31 AM •
Protech...
•
Answered
on Jan 19, 2014
Rheem 41vr40
Did you try amazon.com? they seem to have virtually everything, or at least a link to what you need.
What is error code c8 mitsubish heater
The P8 fault can mean many things when it pops up on your Mitsubishi Electric wall controller. The P8 fault is activated when the indoor coil sensor does not change the temperature for a set amount of time after the compressor is (or should be) switched on.
Rival titan floor heater coils don't turn red
Beware when working with electrical equipment. It may cause electric shock.
Check the power supply wires, connections with heating coils. If they are ok then possibly heating coils require replacement.