Top 20 Nor-Lake Freezer Norlake Refrigeration 6' x 6' Kold Locker Walk-In Freezer - 6' 7'' High w/Floor Questions & Answers

0helpful
1answer

I am working on a norlake walk in and dont have a wiring diagrahm wher do the two wires coming from the pressure control hook in to

The pressure control will be fed a live from the thermostat and feed a live to the compressor relay
4/27/2014 2:11:48 AM • Nor-Lake Freezer... • 253 views • 0 helpful votes
0helpful
1answer

Please help. Have norlake. Model

if the temp is 10f compressor is fine, just need a tune up, call a specialist.
9/12/2011 7:13:27 AM • Nor-Lake Freezer... • 197 views • 0 helpful votes
0helpful
1answer

Where is the thermostate(sensor) located that

The thermostat sensor is located in the top rear of the interior of the unit, if you locate the dial to change temps on the inside of the unit, the sensor is attached to it, you may have to pull your fridge apart to get to it, but it can be done.

Regards Russ
3/7/2011 9:32:41 PM • Nor-Lake Freezer... • 259 views • 0 helpful votes
0helpful
1answer

We are involved in manufacturing of food -

Must be kept at 0*F (-18*C) minimum
12/11/2010 4:46:52 AM • Nor-Lake Freezer... • 122 views • 0 helpful votes
0helpful
1answer

I understand this to be

Helloo roger.....Freezers have a thermostat to maintain the proper temperature. These are usually very simple devices. When the freezer reaches the set temperature, the thermostat interrupts the electricity flow to the compressor, which stops cooling. Set your freezer to a colder and colder setting until it doesn't cut out. If you are already at the coldest setting, your only option would be to change the freezer's internal thermostat to one that has a lower cut out capability. Most refrigeration technicians could find the thermostat for you to do this. Joe

Thanks for choosing Fixya!
12/1/2010 10:48:21 PM • Nor-Lake Freezer... • 74 views • 0 helpful votes
0helpful
1answer

Frost builds up on the vents and sides of the

Change the defrost timer.
8/7/2010 2:36:30 PM • Nor-Lake Freezer... • 163 views • 0 helpful votes
1helpful
1answer

Freezer won't shut off

Hi John,

The symptoms do indicate a failed thermostat.

I am not sure where you could get a thermostat for this freezer but I would try contacting Norlake first. They may guide you to who has one or maybe they can sell you one. If it is a direct replacement it is something that you can do yourself.

http://www.norlake.com/
5/9/2010 9:06:35 PM • Nor-Lake Freezer... • 625 views • 1 helpful votes
0helpful
1answer

My Ammana Freezer is not defrosting. I need to

in most cases its the defrost element as the other units last much longer unless the fan has become jammed this happens when people toss meat hard against the back wall if you know how to do polaity test using a multimeter do test on defrost element its not a thermistate as new age frezzers dont use them they use timers and plastic channels to curculate cool air

good luck need more addvice email me
6/25/2010 12:25:40 AM • Nor-Lake Freezer... • 91 views • 0 helpful votes
1helpful
1answer

Eating frost in the freezer

It is probably no more risky than drinking water from a clear running stream. The frost is formed from water vapour so as it is formes it is pure. I suppose it then depends on how old it is and what has come into contact with it. It should be ok though.
4/26/2010 3:48:35 PM • Nor-Lake Freezer... • 247 views • 1 helpful votes
0helpful
1answer

NOT FREEZIN

Look for thermostat. Usually located near the unit inside the conditioned space where the fans are.
4/23/2010 1:16:43 AM • Nor-Lake Freezer... • 105 views • 0 helpful votes
0helpful
1answer

Refrigerator is not cooling

Good day,
You will need an ohm meter to check the parts.
Your defrost system has failed.
It is made up of 3 components, 2 of which are located behind the rear panel in the freezer compartment.
Remove the rear panel. There is a cooling coil, that has a calrod heating element that runs along it's bottom. As well there is a defrost thermostat ( a small round 1" disk) which is located on the top of the same coil. Both should be checked with an ohm meter to test for continuity. The heater should read no more than 30 ohms, the thermostat ( IT MUST STILL BE COLD BELOW 30 DEGREES) should read zero ohms. Note: The heater rarely fails, the thermostat has a high failure rate.

The third item is a timer, or a solid state adaptive defrost control. Depending on age, and model, it is located , behind the kick plate on the bottom front.
Or, in the fresh food compartment on the roof.
If it is a timer, you can turn the timer shaft when the machine is running until the machine shuts off. With it still turned on, wait 40 minutes.
If the machine turns itself back on, the timer is O.K. if not, the timer is bad, and needs replaced.
If the Main heater checks O.K. and it has a solid state control, then replace the thermostat in the freezer compartment, and the solid state board.

Below is an excellant tutorial on defrost systems.

http://www.appliance411.com/faq/howdefrostworks.shtml
Thank you for using FixYa
1/20/2010 2:19:36 PM • Nor-Lake Freezer... • 666 views • 0 helpful votes
0helpful
1answer

What should the freezer temperature shouls be

Normally, freezers are at 0 degrees. If you have ice cream, shoot for -10 degrees.

hope this is what you are looking for.
2/21/2010 9:25:48 PM • Nor-Lake Freezer... • 186 views • 0 helpful votes
0helpful
1answer

I have a pretty new Amana refrigerator that gets

THE FLAPER IS NOT GOING SHUT
REPLACE THE PLUNGER
1/31/2010 4:02:32 AM • Nor-Lake Freezer... • 95 views • 0 helpful votes
2helpful
1answer

I have a 6x6 norlake walk in freezer. The door

I've worked on freezers for over 20 years and have never heard of a compressor going bad because the door was left open. think about a second opinion.
Also, has the cooling coil inside the box developed and frost or ice build up? If so, it needs to be completely defrosted. If you defrost it manually, use a hose hooked up to hot water. Kill all power and hose all build up off. Remove the sheet metal housing ends and be sure there is no ice inside there too. I would go in this direction first.
IN order to kill a compressor under this condition, something really strange must have happened as anything is possible in a refrigeration system. Good luck and hope this helps.
9/6/2009 4:29:40 PM • Nor-Lake Freezer... • 584 views • 2 helpful votes
0helpful
1answer

Norlake freezer 6x6 not freezing enough

Normally freezers are kept at zero. Most health departments will not allow the temp to be higher than plus 10. If you want to store ice cream, you need to be at minus 10 degrees to minus 15 degrees.

let me know if I can be of any further help.
9/29/2009 9:39:49 PM • Nor-Lake Freezer... • 258 views • 0 helpful votes
0helpful
1answer

Frosting up around condensor etc , and the warning light on.

Are you frosting up at the condensor or did you mean the evaporator? If its the condensor then make sure the coils are clean. Still then you will need a tech to look at the seale system. If its the evaporator and the heater is ok then it could be the timer or the terminator on the compressor. Most of the time its the timer.
9/14/2009 3:21:40 AM • Nor-Lake Freezer... • 243 views • 0 helpful votes
1helpful
1answer

Evaporator motors won't run

Normally, freezers have electric heaters that are energized during the defrost cycle. Once out of the defrost cycle, the refrigeration system comes on but the fans do not. This allows the evap to cool off and to prevent circulating warm air from the heaters. This is controlled by a fan delay switch. It is a small, round device that can have 2, 3, or 4 wires going to it, depending on the manufacturer. It is usually clipped on to the end of the evap coil on one of the "U" bends, near the top, inside one of the ends of the evap. Usually where all the electrial components are located. It come in several variations, but it's main function is to prevent the fans from energizing too early. Usually does not bring fans on till evap hits 20 or so degrees. Check this out and get back to me.
8/13/2009 12:24:09 PM • Nor-Lake Freezer... • 330 views • 1 helpful votes
0helpful
1answer

Frost free freezer is frosting up

Your door seal is not sealing properly . Check and use a hairdryer to soften the seal and the magnetic portion should seal itself against the cabinet .
7/7/2009 12:27:50 AM • Nor-Lake Freezer... • 696 views • 0 helpful votes
1helpful
1answer

My freezer temperature dropped from -17 to -4.....

As long as the temp. stays around 5+ or 5- of 0 degrees everything should be okay.
7/2/2009 11:31:06 AM • Nor-Lake Freezer... • 425 views • 1 helpful votes
0helpful
1answer

Warning light on but food is still frozen

It may just be low on freon (coolant) or you may have a bad compressor, or some back switches to the compressor.
7/5/2009 6:02:34 PM • Nor-Lake Freezer... • 246 views • 0 helpful votes
Not finding what you are looking for?
Freezers Logo

55 questions posted

Ask a Question

Usually answered in minutes!

Top Nor-Lake Freezers Experts

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Eric
ADMIN Eric

Level 3 Expert

39387 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Are you a Nor-Lake Freezer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Nor-Lake Freezers

  • Nor-Lake Freezers

Most Popular Question

norlakemodel klc45 wl auc26

  • Freezers