Top 20 Kipor Generator Diesel Kde5000ta Questions & Answers

0helpful
1answer

Why unit keeps shutting down after it starts.

Your question is general without specific details. Any one of many things will cause your generator engine to stop running. Is this question about a Kipor KDE5000TA? If so, your generator is powered by a diesel engine. There are safety shut downs built into the generator to protect the generator head and engine. Do you have any fault codes showing on your control panel display screen? (Trouble codes P-01 through P-05 will be displayed if there's a detected fault) If you have no fault codes, then you likely have a fuel problem. Do the obvious:
  1. Visually check the fuel level in your tank. DO NOT rely on your fuel gauge. It may be stuck or otherwise not working.
  2. If you have fuel, check your fuel filter. It may be clogged. If your fuel filter is good, you may have water contamination.
  3. Drain your tank and refill with fresh #2 diesel fuel. I use "Diesel 911" with a biocide to prevent water contamination and bacteria growth in my fuel.
  4. Make certain your fuel oil supply and return lines are clear, not leaking, and the fittings are tight.
I know I'm shotgunning, peppering the target. However, I don't have enough information to zero in on a specific area where the problem could be. Good luck!
4/26/2015 5:46:53 PM • Kipor Generator... • 608 views • 0 helpful votes
0helpful
1answer

Some times the starter does not start (it seems like there is no dc volt in the battery))but the battery is OK

Start with the obvious first. Remove and clean your battery terminals and wire connections. Before you reconnect the battery, check your battery voltage across the +/- terminals with a meter. It should read 12 to 12.6 VDC. If it reads less than 11 volts, replace the battery. If the battery is good and the battery connections are clean & tight, you may have a faulty starter or a starter relay.
1/14/2014 9:48:15 AM • Kipor Generator... • 87 views • 0 helpful votes
0helpful
3answers

How to replace brushes in a generator?

Generator replacement brush notice: 1, from the model and material needs and the original brush. 2.It is best to grind the new brush to the Radian size of the old brush. 3. pay attention to adjust the brush grip pressure. 4. the carbon brush size should be equal, not too big or too small. The carbon brush is not subject to force in the process of placement. 5. pay attention to the carbon brush and armature to have obvious contact, do not push the carbon brush in. Generator brush replacement method: 1, the first with a special wrench loose brush braid fastening screws, loose fastening screws should not be loosened excessive, to prevent screw loosening and falling off. 2, take off the carbon brush braid, the carbon brush and the pressure-equalizing spring at the same time. When installing a carbon brush, put the brush into the brush grip. 3, then press the equalizing spring. 4.Use special wrench to fasten the brush and braid to fasten the screw. When fastening the screw, it is not necessary to exert too much force to prevent the screw from being damaged. 5. Check that the brush moves freely in the brush grip, and the spring can be pressed in the center of the brush.
1/14/2013 5:03:02 AM • Kipor Generator... • 223 views • 0 helpful votes
0helpful
1answer

Kipor Generator Diesel Kde6700ta P01 fault

Hope can say more details, so that i can provide a right methods. But if you want to see more faluts about diesel generator, here: https://www.dieselgeneratortech.com/generator-sets/discovery-and-elimination-of-faults-of-the-control-system.html
10/15/2012 9:10:03 AM • Kipor Generator... • 2,107 views • 0 helpful votes
2helpful
1answer

Why does the starter motor sometimes start and other times just stick. If you tap the thing on top of the starter motor it sometimes starts

not being used that often you might need to clean the contacts in the solenoid and the starter
9/1/2012 6:34:46 AM • Kipor Generator... • 227 views • 2 helpful votes
0helpful
1answer

Kipor KDE 12STA - Diesel Generators. L.H Protect light illuminated with emergency stop.

Question edited for clarity. No such word as 'propect'. Normally over speed, over voltage or a voltage leak in the generator windings. Contact the maker. https://www.google.com/search?q=Kipoor+KDE+12STA+-+Diesel+Generators.+L.H+Protect+light ..
3/19/2024 3:38:58 AM • Kipor Electrical... • 19 views • 0 helpful votes
0helpful
1answer
1helpful
1answer

How can fix undercharge code on kipor kde6700ta diessel generator?

The "undercharge" code on a Kipor KDE6700TA diesel generator typically indicates that the battery is not receiving enough charge from the generator's alternator. Here are some steps you can take to address the issue:
  1. Check the battery: First, check the battery to make sure it is in good condition and fully charged. If the battery is old or damaged, it may not be able to hold a charge even if the alternator is working properly.
  2. Check the alternator: Use a multimeter to check the alternator's output voltage. The alternator should be producing around 14 volts. If the voltage is lower than this, the alternator may be faulty and in need of repair or replacement.
  3. Check the wiring: Make sure all wiring connections between the alternator, battery, and generator control unit are clean and tight. Loose or corroded connections can prevent the battery from receiving a full charge.
  4. Check the voltage regulator: The voltage regulator is responsible for controlling the alternator's output voltage. If the regulator is faulty, it may be allowing too little voltage to reach the battery. Check the voltage regulator with a multimeter and replace it if necessary.
  5. Check the fuses: Make sure all fuses in the generator's electrical system are in good condition and not blown. A blown fuse can prevent the alternator from charging the battery.
If you are not comfortable performing these steps yourself, it may be best to consult a professional technician to diagnose and repair the issue with your Kipor KDE6700TA diesel generator.
2/28/2023 4:55:06 AM • Kipor Electrical... • 133 views • 1 helpful votes
0helpful
1answer

Fix overtemp light on in kipor kde6700ta diessel generator

The overtemp light on the Kipor KDE6700TA diesel generator indicates that the engine is overheating. Here are some steps you can take to try to resolve the issue:
  1. Turn off the generator immediately and let it cool down. Check the coolant level in the radiator and top it off if it is low. If the coolant level is consistently low, check for leaks in the coolant system and repair them.
  2. Check the radiator fins for any blockages that may be preventing airflow. Clean the fins using compressed air or a soft brush.
  3. Check the fan belt tension and replace the belt if it is worn or loose. A loose belt can cause the fan to rotate at a slower speed, reducing the cooling capacity of the radiator.
  4. Check the thermostat to ensure that it is functioning correctly. If the thermostat is stuck in the closed position, it can cause the engine to overheat.
  5. Check the water pump to ensure that it is working correctly. A faulty water pump can reduce the flow of coolant through the engine, causing it to overheat.
  6. If you have tried all the above steps and the overtemp light is still on, it may be necessary to replace the thermostat, water pump, or other cooling system components. It's recommended to contact Kipor customer support or a qualified technician for further assistance.
Once you have resolved the issue, start the generator and let it run for a few minutes to ensure that it is operating at the correct temperature. Keep an eye on the overtemp light to ensure that it does not come back on.
2/25/2023 5:53:19 PM • Kipor Electrical... • 77 views • 0 helpful votes
0helpful
1answer

How to fix Kipor KDE 45 ss3 start failure

not told what car or truck this is. moved yah.Kipor KDE45SS3 Diesel Generator 40 kVA?
12/9/2022 7:22:06 AM • Kipor Electrical... • 143 views • 0 helpful votes
0helpful
1answer

KDE6700 diesel generator of kipor. It gives proper output of of 225volts and 50 HZ current. But as I put load the voltage drops and turns off.

When you load a generator it should increase in speed to compensate for the voltage drop, is it increasing in speed?
6/10/2022 6:25:54 PM • Kipor Electrical... • 169 views • 0 helpful votes
0helpful
2answers

Error p-06 on screen. Not starting . Fuel pump not running. How can I clear this faultcode?

what make, year, model ?
11/29/2021 1:30:57 PM • Kipor Electrical... • 143 views • 0 helpful votes
0helpful
1answer

My Kipor 6500T Diesel generator runs but can not turn off by electric switches, and no voltage out, what is the problem? help me please! Thanks

Diesel engines do not need electrical supply to run. What do you mean.
10/13/2021 5:13:27 AM • Kipor Electrical... • 299 views • 0 helpful votes
0helpful
1answer

MY KIPOR GEN KX8500 T 6KW BUT WILL NOT START AT ALL,I HAVE CHECKED OIL FUEL

Engines only need three things Fuel and air mixed Compression A spark at the right time One of those three is missing. Is your Caps Lock broken? Typing in all caps is considered shouting!
8/27/2021 5:36:38 AM • Kipor Electrical... • 89 views • 0 helpful votes
0helpful
1answer

6700 STA. How can I reset maintenance light?

By performing the required maintenance
7/10/2021 7:15:58 PM • Kipor Electrical... • 106 views • 0 helpful votes
0helpful
1answer
1helpful
1answer

Hi, I have a Kipor sinemaster 1000 generator that has been in storage for a few years added fresh fuel and engine started. The 12v dc works however when I plug an appliance in the main power plug there is no power even though the green output led is lit. Anyone know what is wrong thanks

The DC output for battery charging is from the engine alternator and is completely independent from the generator inverter.

As this is an inverter unit the typical polarization techniques for standard generators will not apply.

The ouput indicator being lit means the inverter input output should be good. This further implies a circuit disconnect state at the outlets. Try pressing the overload reset switch to make sure it is not in an odd state.
9/10/2020 7:00:15 PM • Kipor Electrical... • 687 views • 1 helpful votes
Not finding what you are looking for?
Kipor Generator Diesel Kde5000ta Logo

10 questions posted

Ask a Question

Usually answered in minutes!

Top Kipor Electrical Supplies Experts

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Kipor Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Kipor Electrical Supplies

  • Kipor Electrical Supplies

Most Popular Question

starter motor sometimes start other

  • Electrical Supplies
Loading...