20 Most Recent Kipor Generator Diesel Kde5000ta - Page 5 Questions & Answers

0helpful
1answer

Kipor generator shut off after start with over load light.

Check your load and reduce if is more than the generator can handle.
4/6/2017 7:00:05 AM • Kipor Electrical... • Answered on Apr 06, 2017
0helpful
1answer

My diesel kipor 5kva generator wont shut by key ,

Caution the manufacture is recommending a cool down period of about 3 minutes to prevent overheating of the combustion chamber. the following is from the manufacture on shut down procedure. 3.2.8Check Stopping of Generating Set (1)Disconnect the load from the generating set. (2)Turn off the air switch of the generating set. (3)Set the speed lever at RUN position, run the generating set without load for about 3 minutes. Do not stop the engine suddenly, otherwise the temperature will increase abnormally, the nozzle will blocked and the generating set will be damaged. Press down the stop lever. Concerning the electric starter, turn the key to OFF. Turn the fuel **** lever to S position. Pull out the recoil starter handle until you feel resistance (at this position, both intake/exhaust valve are closed.) and leave the handle in this position. This prevents the engine from rust. If the engine keep on running even after the speed lever is placed at the STOP position, either turn the fuel **** to the CLOSE position or loosen the nut of high pressure fuel pipe on the pump side to stop the engine. Do not stop the engine with the decompression lever. Do not stop the generating set with load. Stop it after the load removed. the following link provides the complete maintenance manual for the diesel generator http://www.rcremers.nl/webshop/handleidingen?download=20:handleiding-aggregaat
1/12/2016 2:59:46 PM • Kipor Electrical... • Answered on Jan 12, 2016
0helpful
1answer

My Kipor KDE16STA3 shows p03 error after 15 min runing and shuts down after 3 sec.The voltage drops to 30,40 whta's happening?

[PDF]DIESEL GENERATING SET

www.kipor.com/upload/spec2011053011590766.pdf 3/KDE16STA3/ ..... P-03 Undervoltage: Indicating voltage higher (lower), the generator will self- braking. P-04 Generator ... KDE16STA3 KDE19STA KDE19STA3.

[PDF]2

www.kipor.com/upload/spec2011061109073968.pdf P-03. Decrease load less than the related load, turn on the breaker. P-04. Replace the fuse of the same type. Check the circuit and inserter. Replace the starting ...
10/31/2015 5:35:03 PM • Kipor Electrical... • Answered on Oct 31, 2015
Not finding what you are looking for?
Kipor Generator Diesel Kde5000ta Logo

10 questions posted

Ask a Question

Usually answered in minutes!

Top Kipor Electrical Supplies Experts

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Kipor Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Kipor Electrical Supplies

  • Kipor Electrical Supplies

Most Popular Question

starter motor sometimes start other

  • Electrical Supplies
Loading...