20 Most Recent
Gaggia Titanium Espresso Machine - Page 4 Questions & Answers
Door from grinder will not let coffee into brew unit
From the description I understand that the flap at the outlet from grinder is not easy to open and let coffee grounds out from the grind chamber.
Firstly this is a mechanical obstruction and not related to any electrical or electronic control.
This happens frequently in the Ceramic burr grinders due to the following reasons:
1- The beans used are dark roast oily. Such beans are not good for use i any fully automatic model. This should be stopped immediately.
2- The grind fineness may be set at fine powdery level. This is done because there is wrong assumption thata fine grind makes stronger espresso. That is not applicable in fully automatic machines. The extraction of espresso in fully automatic machine is with pre infusion (also called pre brew soaking) and uses a back pressure valve for 9 bar extraction pressure. For this reason
the coffee grounds should not be finer than table salt grain. If coffee fineness is set at powdery fine, then the setting should be changed to coarser setting.
3- Grinder may not have been cleaned for an extended period. If so clean the grinder. Use brush or scrape solid deposits in corners and crevices to clean.
Finally as a part of cleaning, use a rag wrapped on finger or screw driver to wipe the invisible oil deposits on the grinder parts between the burr and the outlet.
Check the flap in the coffee outlet is hinged correctly and moves freely front and back to make sure that it is not blocking outlet for ground coffee. Btw, I’m available to help over the phone in case u need at
https://www.6ya.com/expert/edward_bbd2c7ff4ee1828a
My machine wasn't used for a while and the
I have just had the same thing this morning with my machine (not used & ventilate message). I followed the instructions & found the same as you, then I realised I had not turned the knob to dispense the water!! Try this, it does take a while for it to go through the ventilate process, I had to refill the watertank.
Good luck
Coffee grounds (unused) dropped into dregdrawer tray
try to make the grinder position on 2.
And where exactly is the unused coffee-in the drawer or under the brew unit? Did you try to wash the brew unit with water-fill a box with hot water and put it into box. Leave it all night and in the morning just clean on the water and dry it.
Let me know what is result when you done it!
Gaggia Titanium - can't get it to move beyond
Select "Hot Water" and open the steam valve. Let it pump water out the steamer for awhile. It usually clears right away but may need to pump a lot of water to clear the error.
If you aren't able to get any water coming out the steam nozzle, you may need to prime the pump with the little squeezy tool they gave you with the machine - or you can use a turkey baster. Mainly you are trying to get water up into the pump to prime it (get the air out of the pump) so it can pump water instead air.
Not finding what you are looking for?