Whirlpool LER4634J Electric Dryer - Answered Questions & Fixed issues
The dryer is causing the breaker to trip
The vents are most likely stoped up . All the lint & anything around the fan all the way to the outside vent needs cleaned . I have found a lot of things in front of the fan nails coins & whatever that were in clothes pockets sometimes the lint or other things won't let the fan turn & the breaker or thermal fuse to blow. Hope this helps
9/24/2021 2:25:16 AM •
Whirlpool...
•
Answered
on Sep 24, 2021
•
781 views
Whirlpool Senseon dryer stuck on one heat cycle
I found a work around that works for me. Press and hold wich cycle you would like, while still holding the button down choose which options you want such as time or heat ect. While still holding the button down press srart.
8/8/2021 12:38:59 AM •
Whirlpool...
•
Answered
on Aug 08, 2021
•
616 views
LER4634JQ0 was overheating and shutting
Remove the back panel.
Check the thermal cutoff it is on the top heating element cover. You can check it with an ohm meter. If it is bad replace it 309 degrees and the hi-limit thermostat (250 degrees) you can get a kit that has both in it. If the hi limit is bad it will blow the cutoff. If it starts after replacing them check all thermostats & remove the blower cover and clean any lint or junk from around the fan. Check the fan it may be broken or stripped Clean any lint you see anywhere lint or junk will not let the heat get out the vent.You may find pencils nails or anything keeping the blower from turning.Be absolutley sure the vent is clean all the way out of the house. Hope this will help you good luck.
8/15/2018 3:40:02 AM •
Whirlpool...
•
Answered
on Aug 15, 2018
•
576 views
Dryer cuts off after 10 minutes
Agree with you. Make sure the lint collector is clean and ditto for the vent. If it goes up to roof have to check it there also to make sure there are no obstructions whatsoever in vent line. Unit is turning off because it is overheating. If lint collector and vent is squeaky clean and unit blows out like crazy then the temp switch is opening up prematurely and might need replacement or jumping - your call. If you want to check for part go here
Search Over 2 1 Million Appliance Parts
9/6/2017 9:34:16 PM •
Whirlpool...
•
Answered
on Sep 06, 2017
•
202 views
How to remove the motor from the fan.
It unscrews. With that being said most times it is on so tightly that you have to break it off. Squeak noise is most likely the rollers or the idler arm.
2/6/2016 11:04:43 PM •
Whirlpool...
•
Answered
on Feb 06, 2016
•
158 views
What does RF error code mean
I do believe you are probably seeing AF. AF is restricted airflow, which can be a number of different things. You might have a gasket leaking between the tub and front panel, maybe the gasket is loose or missing from the door, or clogged fan housing inside. Most of the time, it's usually a venting issue in the home.
11/26/2014 12:38:05 AM •
Whirlpool...
•
Answered
on Nov 26, 2014
•
752 views
Dryer buzzes but won't start
see the diagram :1) O.k if the thermostat 2) Thermofuse is o.k is good resultant BUT please 3) Test the door switch for open or defective , if the remain open the motor will NOT START. see the diagram. 4) After changing the switch if the problem remain the same the motor is faulty( centrifugal swithc, etc) need repair or replace. 5) Test the push button start for diryt or open, test the wires for loose, broke, or burn wires too.God bless you
6/17/2014 7:17:50 PM •
Whirlpool...
•
Answered
on Jun 17, 2014
•
760 views