20 Most Recent
AmcorAire UCHW-H24AF2 Split System Air Conditioner Questions & Answers
We have: AmcorAire Duo Ductless Split Air
Amcoraire Closed their doors Aug/Sept 2009. Pridiom Group started operations October 2009, Pridiom purchased Amcor parts/equipment at bank sale. ANYTHING PRIDIOM SELL'S, PRIDIOM WARRANTS to be free of defects parts 3 years/5 years compressor. It is that simple.
[email protected]
201-266-8234 option 2
Amcor aws181hx
P-4 Error code means your system is low on refrigerant (R-410A)
Conditioner Fan
this a split system? inside and outside unit? possible relay( if it has one) or contactor. make sure 230 volts at contactor.
Split AC system not cooling.
P-7 Error Code means: DC Voltage Problem in the outdoor unit.
Bad PFC & IPM Circuit Boards.
The Pridiom Group
201-266-8234
My Amcor ductless unit aws181hx
FC = Compressor Fault
P-3 = Overload-Current/Voltage/Temperature
Call Amcor Tech Support........Pridiom 201-266-8234 option 2
E 7
Multi Splits and Multi V = indoor unit is set to run in a different mode from the master indoor unit. Set ALL indoor units to cooling or ALL to heating to clear.
Splits = Compressor Over Current (CT2), Check loose wiring/condenser coil for clean