Amana PTH153B50AJ Heat Pump Air Conditioner Questions & Answers
Why does my PTHP. shut off and switch to electric resistance heat?
im guessing its there way of defrosting the coils , as with this type (small) its tough to defrost the coils in an efficient way , hp runs normal to within one or two degrees of setpoint , hp shuts off or reverses in low speed , back up heat comes on to complete the room heat and to generate the heat needed to defrost the coils , entire unit shuts off when set point is reached , reversing valves set for heat and wait till next cycle
now mine does something slightly different : it runs for fifteen minutes and if set point is not reached it switches to back up and reverses the coils ,leaves compressor on (low speed) , this heats the coils up and defrosts the outdoor unit , and if it runs long enough twenty minutes total time , it goes back to normal and aux heat shuts off . this drives me insane thinking how much im spending on heating the outside !! but im sure its needed to prevent ice build up on outdoor coils ,and I sure don't want that cracking with ice formations
1/30/2016 1:32:18 AM •
Amana...
•
91 views • 1 helpful votes
Hear pump keeps running constantly, why won't it shut off?
if some units detect ice they will leave the fan running in an attempt to defrost the coils. If it's the outside coils and it's warm enough inside, try running the air conditioning for a few minutes, that will put hot coolant through the coils and could melt the ice for you.
3/16/2015 5:10:41 PM •
Amana...
•
119 views • 0 helpful votes
Pth153b50aj
Change motor to check do a amp draw find out how many amps motor is drawing this may tell you that motor is going
10/25/2013 1:00:23 PM •
Amana...
•
81 views • 0 helpful votes
My Amana heat pump model
This sounds like a freon problem your system probably has a leak in the system somewhere. Amana has tons of problems with there equipment. They make there coils paper thin and they split especially on a heatpump. Amana used to be a good brand and then got bought out by goodman manufacturing and have turned there product into ****. How old is this unit?
6/14/2011 7:09:40 PM •
Amana...
•
256 views • 0 helpful votes
The ptac unit is not heating or cooling the aux
Verify all your components are operating - Compressor? Condenser fan motor? Blower fan motor?
If not check voltage to any that are not operating.
If all components are operating and the coils are clean - the refrigerant level is most likely low.
10/28/2010 12:28:27 AM •
Amana...
•
487 views • 1 helpful votes
Blower motor runs but dies out..
When it does this carefully feel the end of the blower motor. If it is too hot to touch,Replace the blower motor.
Your 5 minute off sequence allows the motor to cool enough for a restart.
4/8/2009 8:00:06 PM •
Amana...
•
433 views • 3 helpful votes
No heat
1.check heatar of unit.
2.wireing of heater.
heater not workink.
thermostate also check
2/21/2008 7:50:14 PM •
Amana...
•
459 views • 0 helpful votes
Amana PTH153B50AM PTAC where the heat runs intermittently.
i'm not familiar with your specific unit but ..sounds like an electronic gas value has gone bad or has a bad connection when that happened to my friend it wasn't that expensive to have it fixed .. BYW it acted like this for a while then stopped working completely