Amana PTC153B35AJ Air Conditioner - Answered Questions & Fixed issues
Heat won't come on
If it is a reverse cycle unit the magnetic reverse cycle switch is faulty and should be replaced
5/16/2014 4:43:27 AM •
Amana...
•
Answered
on May 16, 2014
•
168 views
What does diagnostic code lf mean
1blink/sec---normal, 2blink/sec--blown fuse--3bliks/sec--replace evaporator sensor,4blinks/sec--mode switch failure, replace board,5blinks/sec--pot. failure,replace board;6blinks/sec--bad thermostat input; 7blinks/sec--factory only;8blinks/sec--bad room thermostat. The blink pattern repeats every 5 seconds.
2/2/2013 3:43:24 AM •
Amana...
•
Answered
on Feb 02, 2013
•
437 views
I have no 220 coming out of the circuit board heat
Jumping 220 volts directly to heat or cool for just checking purpose. Not for regular use. Please replace your thermostat immediately.Please don't take risk.
To get heat set temp 30 degree and mode in "Heat"Hope you will keep my sincere advise.
1/14/2011 11:04:37 AM •
Amana...
•
Answered
on Jan 14, 2011
•
83 views
Amana80 SSE Air Command Gas
Hello and sorry to hear about your problem.
It sounds like your glow rod, is defective. This is the electronic pilot lite for the unit.
I suggest you can in a service person. If you live in the Denver Co area, I can help you.
I have tried to help you. Please help me by Vote/Rate this response. Thanks and good luck.
34234jiii
12/21/2010 8:24:58 PM •
Amana...
•
Answered
on Dec 21, 2010
•
517 views
HOW DO RESET LIMIT SWITCH
The limit switch will have a small button in the middle. Push to reset. If no button and limit is open. Bad switch. Replace it. Russ
3/25/2010 2:29:30 PM •
Amana...
•
Answered
on Mar 25, 2010
•
366 views
My Amana Confort Zone ptac unit with model number
there is a drain plug inside unit.pull unit out of hole and look down to right side of unit in the drain pan you will see a plastic drain port knock it out and the unit will drain
1/24/2010 8:20:58 PM •
Amana...
•
Answered
on Jan 24, 2010
•
503 views
I had the turned on this morning but it will no
Do you have power going to it?. Sometimes if a cheap outlet is used it will break the connection when a loasd is put on it. With the unit plugged in and in on position, wiggle the cord st the outlet. Confirm you have power to the AC Unit, Let me know.
11/7/2009 9:36:04 PM •
Amana...
•
Answered
on Nov 07, 2009
•
144 views
Excessive water dripping from Central A/C drian line
sounds like the overflow drain is picking up the water that means the main drain is clogged.you need to find the main drain pipe if lookin at the air handler in attic there should be 2 drains from unit one higher than other follow it and blow out drain they put the other overflow drain out the eve so if it stars leaking someone notices it and it doesnt damage cieling but it sound like it needs imediate attention befor it does go to the overflow pan and damage your cieling. i hope this helps and good luck
7/3/2013 2:07:57 AM •
Amana...
•
Answered
on Jul 03, 2013
•
1,369 views
Rusted drip pan
it is call a base pan part #20403508..
let me know if it helps
9/23/2009 1:23:09 AM •
Amana...
•
Answered
on Sep 23, 2009
•
62 views