20 Most Recent Marantz SR8001 - Page 6 Questions & Answers

0helpful
1answer

Just had Marantz 2235B serviced however after 2 hours of playing some vinyl, I hear fuzz and a pop in the left speaker. Now, no more sound from receiver.

Fuzz and pop sounds like bad capacitor or blown transistor. Best to take it back to service center. While there, throw your toys out of the cot, explaining that they did a 'b*m' job.
7/15/2018 11:46:00 PM • Marantz Audio... • Answered on Jul 15, 2018
0helpful
2answers

Marantz 4400 Distortion and scope adjustment issues.

The unit will need servicing, I would not recommend you poking around with the scope circuity as there is up to 580v there and it will ring your bell. I have worked on several 4400's and nursed them back to good health. www.back2lifeelectronics.com
7/11/2018 1:31:40 PM • Marantz Audio... • Answered on Jul 11, 2018
0helpful
1answer

Need a user manual MARANTZ SR82

Service manual, (not a User Manual), available by login at the site below: https://www.hifiengine.com/manual_library/marantz/sr-82.shtml
6/24/2018 4:45:59 PM • Marantz Audio... • Answered on Jun 24, 2018
0helpful
1answer

Download for Marantz 6100 service manual

6/18/2018 1:49:41 PM • Marantz Audio... • Answered on Jun 18, 2018
0helpful
1answer

How do I reset a Marantz sr6007 to factory reset

Hi Neville. go to this link and its the manual this might help you out. Marantz SR6007 Owner Manual Troubleshooting Or this link might help you out. How to reset Marantz sr6007 to factory reset Google Search
5/10/2018 8:13:30 PM • Marantz Audio... • Answered on May 10, 2018
0helpful
1answer

After a brief power outage, my Marantz receiver, model SR-48, is stuck in standby mode. Tried unplugging it, but to no avail. What do I have to do to reset it? No owner's manual found online.

I think your radio is as much computer as radio. Computers are everywhere and contain delicate CMOS circuitry - easily damaged by a power surge such as often accompanies a power outage. Surge protectors should be used to provide a measure of protection, although it is possible a software fault has been caused by the sudden interruption of supply.
5/7/2018 8:25:11 PM • Marantz Audio... • Answered on May 07, 2018
0answers
0helpful
1answer

I have a Marantz # 2238b shorted the speaker wire and now blows the main fuse when I power it up.

That will have knackered the main power output device(s) located on the big heatsink. If they are transistors you should be able to tell which are faulty as a meter on the pins will give a full scale deflection, just like it was a piece of wire. There could also be physical signs of damage such as parts blown apart or burning.
4/29/2018 5:34:25 PM • Marantz Audio... • Answered on Apr 29, 2018
0helpful
1answer

I have a marantz sr-68 receiver and occasionally when playing through Sonos it fails and goes to protected mode. Any suggestions on how to prevent this.

Is the amplifier being overloaded by the speakers, generally if they shut down like this its because the amp can't supply enough power to the speakers or there is an issue with the wires being to light gauge.
2/9/2018 8:49:04 PM • Marantz Audio... • Answered on Feb 09, 2018
0helpful
1answer
0helpful
1answer

I have Marantz SR6003, when I turn on the power the standby light keep on blinking rapidly, any help will be appreciated. Thanks

I'm an authorized service center for Marantz although I mainly work on vintage equipment, according to the manual the code your getting is for speaker impedance imbalance , but if you don't have speakers hooked to it then you have issues with one of the channels output stages, it may not be something you can fix yourself unless you have some fairly advanced electronic skills
2/1/2018 7:46:34 PM • Marantz Audio... • Answered on Feb 01, 2018
0helpful
1answer

Marantz PM7200 Stereo Amplifier: Can a production fault with an amplifier cause it to keep blowing the speaker on one side, while the other side's speaker is fine?

It could be the amplifier but most likely it’s going to be either the connections or a power supply issue. Do you have anything plugged into the same outlet? What type of power strip are you using. The amp will usually go into a protect mode as to not damage anything before it would create the environment to cause a blown speaker. I know that with your model, along with multiple others, have had issues with the power board needing replacement.
1/13/2018 2:11:45 PM • Marantz Audio... • Answered on Jan 13, 2018
Not finding what you are looking for?
Marantz SR8001 Logo

25 questions posted

Ask a Question

Usually answered in minutes!

Top Marantz Audio Players & Recorders Experts

 Grubhead
Grubhead

Level 3 Expert

5755 Answers

Brad Brown

Level 3 Expert

19187 Answers

xxxxxx xxx

Level 3 Expert

5117 Answers

Are you a Marantz Audio Player and Recorder Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Marantz Audio Players & Recorders

  • Marantz Audio Players & Recorders

Most Popular Question

harman kardon avr 350 unit powers off

  • Audio Players & Recorders
Loading...