Hp D5160 prints testpage after each print
Salve La stampante Photosmart HP D5160 dopo l'accensione inizia a produrre rumori come ingranaggi che si graffiano ripetutamente nell'area vicino al cassetto di sostituzione delle cartucce, alla fine dopo alcuni istanti la stampante smette di fare rumore ed ? pronta per la stampa, ma ultimamente, dopo sopra, sistematicamente non viene pi? stampato e il punto esclamativo rosso lampeggiante rimane. Le cartucce sono originali e hanno una capacit? superiore ai 3/4. Spero in tuo aiuto il prima possibile. Grazie. Roberta
Red light blinking
The Attention light is flashing red.
Solution The printer requires attention. Try the following:
* If the printer is connected to a computer, check the computer screen for
instructions.
* If you are printing a CD label on a CD/DVD, insert the CD/DVD holder in the
CD/DVD tray now.
* If you have a digital camera connected to the printer, check the camera screen
for instructions.
* If the printer is not connected to a computer, check for the following problems:
- Main cover open
- Out of paper
- Paper jam
- Print carriage jammed or stuck
- Print cartridge missing or inserted incorrectly
- Print cartridge tape not removed
- Incorrect print cartridge installed
- Packaging materials are not removed
* If you are unable to solve the problem by using the instructions above, turn off
the printer and unplug the printer power cord. Wait 10 seconds, and then plug
it in again. Turn on the printer.
I received an error code on my HP Photosmart D5160
I've got the same error code. I disassembled plastic body to reveal mechanism. At the end of initialisation procedure I noticed that the cleaning caret was stuck and a ckracking sound appears. I took off a small triangular cogweel panel at the right hand end of the mechanism that actually gears the cleaning caret. I disassembled the panel and discovered a brocken cogweel. Also I noticed that the cleaning caret itself was hard to move. I applied some grease, but now I need the brocken cogweel to be replaced or fixed.
The resume: if you are not into fixing your equipment and got such an error - probably a service center is waiting for you.
Hi: Re HP Photosmart D5160 printer: 1) Prints a
You may have added a separator page,
1). Open printers and Faxed.
2). Right-click your printer and select 'Properties'.
3). Click 'Advanced' tab
4). click 'Separator Page'
Delete any text in the box and click 'OK'
I don't have the disk
You can install these printer by downloading the printer software/driver from this link and then run that to install the printer, just click
HERE and select the operating system of your computer and proceed with the download.
Why is my D5160 printer
sto cercando di stampare documenti ma non parte. ho sostituito la cartuccia di nero, ma il punto esclamativo rosso, lampeggia sempre. la sprngo manualmente,ma dopo si riacende da sola.che cosa ha?grazie
HP Photosmart D5160
gives error message
Issue
The product displays an 0x ... error code when printing (for example
Error: 0xf0af8004). These error codes indicate that the product has an
internal condition.
Solution
Use the instructions below to resolve the issue by restarting the product.
Disconnect the Universal Serial Bus (USB) cable from the back of the product, but leave the product turned on.
Open the cover of the product and remove the print cartridges.
Close the cover and wait for the Insert Ink Cartridges message to display.
Disconnect the power cord from the back of the product and wait for one minute.
Reconnect the power cord. If the product does not automatically turn on, press the Power button.
Open the cover and reinsert the print cartridges.
Close the cover.
If prompted, print a calibration page.
Reconnect the USB cable, and try to print a print job from the computer.
If these steps did not resolve the issue, contact HP technical support for assistance.
Trying to print photos on photosmart d5160, it not
Hi Michael,
This is an indication of out-of-regulation in the power supply section. The very
common caused of this fault is the leaky
electrolytic capacitor in
that section. It will drop the supply from normal voltage and
will disable the unit. Sometimes it has a bulged/dome at the top but not all, it is better
that you have a capacitor
checker/tester to determine
its condition. Also, bad
solder joints can produce the
same symptom, it is hard to spot, you should use table lamp/portable lamp for
finding the cold solder.
If you don't have necessary tools
and test instruments, and can't do the job yourself, I would advice you to
look for a professional to troubleshoot the problem. Don't
attempt to work in the power supply if you don't know the safety precaution of handling it, there some stored
electricity enough to hurt you with a little mistake only.
Hope I helped you.