Top 20 Comfort-Aire BHD-651 Dehumidifier Questions & Answers

0helpful
1answer

Where is the float

Don't know your model specifically, but the float is usually at the top of your water tank and activates the system to shut down by popping up when the tank is full. With some tanks you can actually reach in and sort of clean off the float. Jelly-like stuff can build up on the float after a number of years. Cleaning it off wouldn't hurt.
9/9/2013 8:47:36 PM • Comfort-Aire... • 230 views • 0 helpful votes
0helpful
1answer

Method to recharge the freon on my Comfort Aire

Hi,
Here is a tip that I wrote about how to add refrigerant to a air conditioner orcooling system

How to add Freon to a Air Conditioner or Refrigeration System

heatman101
6/25/2011 10:20:23 PM • Comfort-Aire... • 903 views • 0 helpful votes
0helpful
1answer

The unit is showing "full

Two things generally cause this problem. If your unit has a Float Valve inside the bucket, it's stuck in the 'Up' position, which under normal conditions, indicates to the unit, that the bucket is FULL. If you don't have that, then when the bucket was last inserted into the bucket holder, it did not trip the bucket removal safety switch. Remove the bucket and reinstall it, making sure that it fits squarely into the hole from top to bottom. Leave the unit ON when you do this, because if you do it correctly, the unit will automatically start and run. Also, be sure that humidity extraction level is set on 32 - 35 %.

Hope this helped you to troubleshoot and solve the problem. Please let me know. Thanks.
6/13/2011 6:30:38 PM • Comfort-Aire... • 960 views • 0 helpful votes
0helpful
1answer

Model BHD 651-C Serial 611TA000375 Problem:

Hi,
There are many reasons why a dehumidifier willnot work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrongwith their dehumidifier

Dehumidifier is running but no water is in bucket

heatman101

';';';';';';';
';';
6/9/2011 1:15:07 PM • Comfort-Aire... • 598 views • 0 helpful votes
0helpful
1answer

Unit shuts off. CH

Hi,

Here is a tip that explains what can be happening to make the dehumidifier showthat the bucket is full when it is not.

Dehumidifier Problem It shows Bucket Full

heatman101
6/25/2011 1:05:42 AM • Comfort-Aire... • 209 views • 0 helpful votes
0helpful
1answer

Unit runs but does not pull water out of the air

Hi,

Here is a tip that explains what can be happening to make the dehumidifier showthat the bucket is full when it is not.

Dehumidifier Problem It shows Bucket Full

heatman101

'
5/15/2011 2:54:03 PM • Comfort-Aire... • 186 views • 0 helpful votes
0helpful
1answer

I noticed that the "bucket full" light is on and

Hi,

Here is a tip that explains what can be happening to make the dehumidifier showthat the bucket is full when it is not.

Dehumidifier Problem It shows Bucket Full

heatman101
3/31/2011 9:48:09 PM • Comfort-Aire... • 298 views • 0 helpful votes
0helpful
1answer

UNIT ICED UP. TEMP. IN CRAWL SPACE ABOVE 60

When you powered down the unit, did you just turn if OFF using the controls on the unit Or did you unplug it entirely? If you didn't unplug it, it won't reset itself. Leave it unplugged for at least 30 minutes. As far as the blinking bucket full light is concerned ... It's possible that the bucket is slightly out of kilter and is only making partial contact with the safety switch. Especially if it's sitting on uneven soil or when the bucket get partially full the weight of the bucket is pulling it out of kilter because it's sitting on soil, rather than a hard floor. If nothing else, place it on a 1/2" piece of plywood or OSB and level it.

To be totally candid, I have some concerns about leaving a dehumidifier running, unattended in the crawl space of a house. There's to many things that could go wrong that would have disastrous results.
3/10/2011 9:29:51 PM • Comfort-Aire... • 157 views • 0 helpful votes
0helpful
1answer

Code CH 01 is showing where the humidity level is

Had same problem in 2008. Had to replace Evap Thermister board and sensor. Parts $120 Labor $50.00.
I am not an expert. Good Luck!
8/30/2010 8:43:52 PM • Comfort-Aire... • 178 views • 0 helpful votes
0helpful
1answer

Fan blows but the compressor doesn't kick on.

You have a leak in hte sealed system. get an authorized refrigeration center to repair it for you.
8/11/2010 3:02:18 AM • Comfort-Aire... • 119 views • 0 helpful votes
0helpful
1answer

Unit only runs a few seconds and then shuts off

If the water reservior is empty then the float is stuck in the full position.
5/26/2010 1:14:25 PM • Comfort-Aire... • 551 views • 0 helpful votes
0helpful
1answer

Dehumidifier throw breaker

Hi,
Sounds like the compressor and if it is that oyu are better off buying new...
There are many reasons for a dehumidifier2_bing.gif to not work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrong with their dehumidifier2_bing.gif.

Dehumidifier is running but no water is in bucket
http://www.fixya.com/support/r4662409-dehumidifier_running_but_no_water_in

heatman101
5/13/2010 4:22:45 PM • Comfort-Aire... • 146 views • 0 helpful votes
0helpful
1answer

Iced up, filter blocked, now leaks down the side,

Hi,
Here is a tip that I wrote that will help you...

http://www.fixya.com/support/r3877515-dehumidifier_problems_dehumidifier

heatman101
2/16/2010 12:44:38 AM • Comfort-Aire... • 91 views • 0 helpful votes
0helpful
1answer

My BDH-651 is now (after 3 years) forming Ice at

It is either dirty or low on freon, did you check for filters?
12/3/2009 12:24:36 PM • Comfort-Aire... • 135 views • 0 helpful votes
0helpful
1answer

Bucket Full light stays on but bucket is not full

You are on the right track.
10/2/2009 5:46:21 PM • Comfort-Aire... • 520 views • 0 helpful votes
0helpful
1answer

Comfort-aire BHD-651 Dehumidifier broken after power outage

Start with the outlet they are plugged into - any power there?
The only solution I can suggest is to take it apart and check the wiring for any burned or shorted wires.
Also check the control circuit board - most have a small glass tube fuse on them. It is possible it was blown when the house was hit.
8/24/2009 9:48:17 PM • Comfort-Aire... • 227 views • 0 helpful votes
0helpful
1answer

Bucket full light will not

The bucket full light is controlled by a manual 'float' switch in the bucket itself
-when the water level rises...it lifts the float ...turns on the light and does not allow the unit to operate because it believes it is full.

It is very common for the 'float' to gets misaligned, hung-up, etc. when you remove and re-insert the bucket. Sometimes the 'chain' gets twisted, turned...which does not allow the float to ...float...rather it is 'hung-up' which indicates it is 'full'...when in fact it is clearly not.

To check this:
  • remove bucket from unit
  • look into the top of the bucket opening to locate the 'float'...generally 2" round plastic ball on a shaft, (or chain)
  • softly cup the float in order to lift this up...with the unit stilll plugged in...to see if the light goes off...this is very likely
  • then be sure that the float mechanism is able to freely 'float' in the space....i.e. you are trying to simulate the impact of rising water levels in the bucket
  • as it rises (in your hand the machine will turn off/light on...as it drops....the light shuts off, allowing the machine to run (when humidity levels demand it)
  • then re-install the bucket....being very careful to lift the float, while you insert it...there is generally a little nack to it...but you quickly learn how to do it easily (I just reach into the space...cup the float...put the bucket on an angle...slide it in....release the float into the bucket...(remove hand)...then finish pushing the bucket into place
-hope this helps
11/8/2008 2:14:59 PM • Comfort-Aire... • 1,282 views • 0 helpful votes
6helpful
1answer

Unit Runs (fan and condenser) but no water?

By condenser I assume you mean the compressor is running. Is there ice forming on the front coil?
1/8/2008 5:18:57 PM • Comfort-Aire... • 1,760 views • 6 helpful votes
0helpful
1answer

Fan does not come on

I've seen abunch of these. The fan motor has a fuse wound into the windings. It cannot be replaced you need a new fan motor. The motors seem to run hot normally, leading to a short lifespan.
 I suggest buying a better brand unit.
10/23/2007 12:50:46 PM • Comfort-Aire... • 478 views • 0 helpful votes
Not finding what you are looking for?
Comfort-Aire BHD-651 Dehumidifier Logo

Popular Tags

34 questions posted

Ask a Question

Usually answered in minutes!

Top Comfort-Aire Dehumidifiers Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Are you a Comfort-Aire Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Comfort-Aire Dehumidifiers

  • Comfort-Aire Dehumidifiers

Most Popular Question

bucket full light will not

  • Dehumidifiers
Loading...