Top 20 LG LSC183VMA Split System Air Conditioner Questions & Answers

0helpful
1answer

Airwel gc12 dc inv...the foult shown by diagnostic

Compressor lock out means the compressor is bad and would need to be replaced
1/4/2018 3:33:04 AM • LG LSC183VMA... • 827 views • 0 helpful votes
0helpful
1answer

Super general

Hi sir we have super general mounted split ac e6
7/3/2014 11:28:05 PM • LG LSC183VMA... • 2,798 views • 0 helpful votes
0helpful
1answer

My lg ht805th will not turn on

Switch the power off for 60 seconds and turn back on, also remove the battery from remote if you have one and replace
3/23/2014 12:01:28 PM • LG LSC183VMA... • 61 views • 0 helpful votes
0helpful
1answer

E1 fault on my carrier control

what is E2 error
1/31/2014 9:38:12 PM • LG LSC183VMA... • 136 views • 0 helpful votes
0helpful
1answer

E6 error on idec

E6 error code comes for room sensor in this. It means there is any damage in sensor. Pls replace it
10/13/2013 1:53:16 AM • LG LSC183VMA... • 821 views • 0 helpful votes
0helpful
3answers

E5 error code in bluestar Ac

C5 error blue star air condition
3/29/2013 2:46:13 PM • LG LSC183VMA... • 5,792 views • 0 helpful votes
0helpful
1answer

LG LW1810HW heat/air conditioner... The unit is

Supply fan motor is either shot or needs to be cleaned. Generally if the whole wall is shaking there is a bearing out on the motor. I’m happy to assist further over the phone at https://www.6ya.com/expert/robert_54ae41aaaffbab00
8/23/2013 7:27:06 PM • LG LSC183VMA... • 90 views • 0 helpful votes
0helpful
1answer

Error code 6 for lg split inverter

WHICH GAS IS REQ FOR INVERTER LG AC
2/15/2012 1:33:45 PM • LG LSC183VMA... • 726 views • 0 helpful votes
0helpful
1answer

Error code C5 comes on

You must replace the pc board of the outdoor unit.
5/12/2011 6:47:43 AM • LG LSC183VMA... • 3,336 views • 0 helpful votes
1helpful
1answer

What does the error code

could not find the error code but I did find a manual, hope it helps Tim:

http://webshop.bauer-energi.no/PDF/Service%20Manual%20N12AWV_N09AWV.PDF
4/27/2011 11:06:58 PM • LG LSC183VMA... • 1,427 views • 1 helpful votes
5helpful
1answer

Our LG Art cool Airconditioner

Inverter compressor run current high. Check compressor windings all equal 1 to 4 OhmsCheck to earth 50 MOhm minimum, check run current. If high, winding is weak. Solution: Replace compressor.
1/11/2011 10:28:46 AM • LG LSC183VMA... • 3,714 views • 5 helpful votes
0helpful
1answer

What does a df error

Friend!,
Please ensure with your model/brand and error code. To my knowledge and web search, I don't find tour model on market. Don't be angry, plz check once again and write back.
12/15/2010 6:19:02 PM • LG LSC183VMA... • 1,415 views • 0 helpful votes
0helpful
1answer

Hi. I have a LG

Hi, this error is a communication error between your indoor and outdoor unit, check all wiring and connections - ch 5 is a communication error between the indoor unit and the outdoor unit. You can try turning the breaker off for a few minutes and restart the unit. However if that does not work its best suggested to have an authorized HVAC technician service the unit.
12/28/2010 7:20:18 PM • LG LSC183VMA... • 300 views • 0 helpful votes
2helpful
1answer

What is error code ch

CH-05 Communications Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4
10/6/2010 7:15:48 PM • LG LSC183VMA... • 1,130 views • 2 helpful votes
2helpful
1answer

Il mio condizionatore lg continua

Il mio condinoziatore LG segnala CH 05 cosa vuol dire
8/23/2010 5:30:00 PM • LG LSC183VMA... • 2,053 views • 2 helpful votes
29helpful
6answers

IDEC aircon E5 error what does it mean?

i am air con tech and i face all ready this problem may be it will help u . e5 error is ur air con not have gas becoze of that the low presser switch give error on disply thanks best regard for all. pls let now if its help full
5/27/2010 9:09:02 AM • LG LSC183VMA... • 6,696 views • 29 helpful votes
0helpful
1answer

Air con unit saying 'C6"

According to the service manuals:

6 is:
Excessive current at inverter
DC power circuit

so the unit shouldnt run?!?

The fault is also coming up as:
indoor unit coil sensor faulty

source:
http://www.mylg.co.uk/data%20for%20site/LG%20Fault%20Codes%20for%20SMS%20%2807%20Sept%29.pdf

all the best


7/5/2010 8:53:56 AM • LG LSC183VMA... • 639 views • 0 helpful votes
Not finding what you are looking for?
LG LSC183VMA Split System Air Conditioner Logo

62 questions posted

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

MattS1978

Level 1 Expert

7 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

LG Heating & Cooling

  • LG Heating & Cooling

Most Popular Question

c4 error code lg artcool airconditioner

  • Heating & Cooling
Loading...