Honda EM5000SX generator - will not idle up when a load is placed on. Will produce power but will not idle up.
from your description and what you do , the problem is in the auto control unit
it will be in the system to reduce the rpm to idle when there is no load ( auto mains on off controller switching between genset and mains supply)
by turning the auto operation off you are committing the gen set to full rpms regardless of the power requirement
you have the option of having it fixed at an gen set repair shop or leaving it off and starting the genset only when you have a mains power outage
check with an electrician to ensure that it is possible to run it that way as if the mains power unit is not correct , when you start it and you still have mains power , it will destroy the gen set
How do i seperate honda gx 160 engine from generator
Dear Sir/Madam,
To dismantle the Alternator:
End Plate and Windings:
1. Remove the End cover and note (or better take a picture) of the wiring layout.
2. Undo the engine mounts from the frame and raise the alternator with a block of wood so the mounting studs are free.
3. Undo all wiring and remove the brushes.
4. Undo the 4 outer bolts holding the alternator together.
5. Using a second piece of wood and a hammer, hit the inside of the outer casing where the 4 bolts were attached. Hit opposites (a bit like on a car fitting a car tyre) until the end casing comes free. DO NOT SPRAY OIL DURING THIS PROCESS AS MAY HARM THE ALTERNATOR WHEN NEXT FIRED UP. The windings should also drop off during this process, slide off and place carefully in a safe place.
To Remove the Rotor:
Only do this if you require the Rotor off the Generator! Due to the design the rotor gets tightened onto the crankshaft with the turning of the engine, so they can get stuck pretty solid! There are a few ways to remove the Rotor (Armature). Below we have found a video that will assist you:
https://www.youtube.com/watch?v=A2OUolBIgkE
If that doesn't work, try this method: https://www.youtube.com/watch?v=RsNJLd7j0Yk
Honda generator wont start it was running fine.
If you filled the fuel tank with gasoline enhanced with ethanol the fuel may be bad and caused the carburetor to gum up. Also Honda engines have a low oil sensor and from your description of the oil, can cause problems with the sensor and the engine won't start. Try changing the oil first and then adding a small engine gasoline additive that helps with stale gasoline starting problems.
How many watts are needed to start the aircon unit
The minimum wattage needed to start a air-conditioning unit is usually 3000 watts but there can't be anything else at all using power at the time. If this is on an RV there are components such as the refrigerator, water heater, power inverter and house battery charger that will automatically start when the RV is connected to the generator. These may need to be manually shut off sometimes at the main power box.