My 5.5kva Honda generator has no voltage and voltage meter also not showing voltage. What can be wrong?

Hi there I had a similar problem years ago. 1) check brushes on the sliprings of the alternator 2) There is a small pcb on the brush gear and an electrolytic capacitor some diodes etc. check for bad joints or capacitor 3) lift off one brush from sliprings and connect for a couple of seconds a 12 volt battery to it. Why? The rotor must have some residual magnetism for it to develop excitation and sometimes if the genny was not used at all for a long time then that magnetism sometimes die away. It also happen if the genny was disassembled for one reason or another Good luck
2/7/2018 6:02:37 PM • Honda Electrical... • Answered on Feb 07, 2018 • 213 views
0helpful
1answer

Hi I have a Dunlite UH5 generator coupled to a Honda GX 340 Generator is noisy. Is there a parts list or workshop manual I can get to explain how to identify and repair the generator ?

Hi, You can get parts from "Generator Guru" for your Dunlite generator and your Honda, as it sounds like the anti vibration engine mounts are shot. Sorry, but I can't help you with the manuals. Kind regards David
1/16/2018 8:46:10 PM • Honda Electrical... • Answered on Jan 16, 2018 • 491 views
0helpful
2answers

How to make my black max 8125 generator quieter!?

My friend has one, and after he starts it, he places a small mini shipping crate over it (like the kind you see in photos of cargo ships). Seems like the crate is made of some kind of plastic or fiberglass, and he has a short flexible steel pipe going out of a small hole that is cut out of the bottom of the back side for an exhaust. Seems to squelch the sound fairly well. Good luck.
1/11/2018 1:31:08 PM • Honda Electrical... • Answered on Jan 11, 2018 • 829 views
0helpful
1answer

EG4000cl honda generator do you need to take of the front panel to remove the tank

yes the tank when all of the bolts removed will slide off the rubber mounts and out one end refitting is to remove the rubber , slide the tank back in and then put the rubbers back under the flange of the tank
1/6/2018 4:47:48 PM • Honda Electrical... • Answered on Jan 06, 2018 • 276 views
0helpful
1answer

Honda Powerboss Generator. The engine starts & runs great but generator does not provide power to the outlets. Problem is intermitten but I can tell when it is not going to work by taking the loa

hi problem with voltage regulator/ generator as when this functions properly it will raise engine speed hence giving out the power out put required
1/3/2018 1:48:07 AM • Honda Electrical... • Answered on Jan 03, 2018 • 319 views
0helpful
1answer

Honda ES6500 blows 15amp fuse as soon as the key

hi I think the problem is on when the key is turn to rotate and to engage the starter motor and it at this point that the cable curring the current on to the starter motor it then the fuse gets blown , in my opinion this cable is shortening across the chassis causing the fuse to blow, or when it get to the starter solenoid a faulty solenoid absorbs accessed electric current causing the fuse to blow
1/3/2018 12:37:59 AM • Honda Electrical... • Answered on Jan 03, 2018 • 3,075 views
0helpful
1answer

Honda generator not producing electrical current

Generators rely on a residual magnetic field to "kick start" the current making process. Yours has lost this field. Easy enough to fix however. Plug in an electric drill while it's running. Squeeze the trigger and manually twist the end of the drill (this will act as a miniature generator, as the Honda has lost its magnetic permeability and this motor rotating in reverse will generate a small current and restore it). Take care as, as soon as you spin it fast enough to develop a current, the generator will pick up on this current and start generating it's own current; energizing the drill. Once the generator starts generating current, it will repair itself.
12/27/2017 2:57:45 AM • Honda Electrical... • Answered on Dec 27, 2017 • 1,259 views
0helpful
1answer

Honda ex5500 generator over voltage output

adjust the rpm back to 115-120 volts or increase voltage to 220-245 volts
11/25/2017 3:33:15 AM • Honda Electrical... • Answered on Nov 25, 2017 • 1,408 views
0helpful
1answer

Where do I find free help to repair a EU2000i Honda generator?

Visit YouTube.
11/15/2017 9:34:05 PM • Honda Electrical... • Answered on Nov 15, 2017 • 188 views
0helpful
1answer

Honda generator eu3000is Not getting power to carb in order to meter fuel

After reading about Honda's Eco Throttle system available on inverter generators it seems it is not a fuel metering system but a computer controlled speed regulator or basically an electronic throttle. Because the engine of an inverter generator doesn't need to run at a constant high speed to produce the correct 50 or 60 Hz output this generator can run at slower speeds when the load is light. The electronic throttle is the means to make it happen - operated by the computer. The throttle is probably operated by a stepper motor and the power supplied to it likely to be in digital form. I suggest you try and gain a more full account of how the system works before you delve deeper.
11/9/2017 8:21:39 PM • Honda Electrical... • Answered on Nov 09, 2017 • 1,642 views
0helpful
1answer

What is the gap between the module and flywheel on a eu6500is Honda generator

I don't know. The air gap isn't usually critical. It needs to be a small gap for best efficiency but must not be so close it will touch if expansion brings it closer at operating temperature. The last air gap I adjusted was on a Briggs engine and that was 0.008", 8 thou which I believe is fairly typical for that type of application.
11/9/2017 6:09:44 PM • Honda Electrical... • Answered on Nov 09, 2017 • 742 views
0helpful
1answer

Honda generator repair manual eb3000c

a good book on smaller generators is clymers manual. you may check to see if that one is listed.
11/7/2017 2:33:35 PM • Honda Electrical... • Answered on Nov 07, 2017 • 833 views
0helpful
1answer

Honda generator EB3500 wont idle when put into auto idle, it will basicly want to stop

Carburetor is probably gummed up. Try running some "Sea Foam" in your gas, run it until the mix is in the carb and then shut it off and let it sit. I had to let a snowblower sit a week until it dissolved all the gum. If your using gas with Ethanol, this is a common problem. Try finding a station that sells gas without Ethanol or use Sea Foam to keep the Ethanol from breaking down. (It can break down in as little as 30 days).
10/30/2017 6:28:56 AM • Honda Electrical... • Answered on Oct 30, 2017 • 1,294 views
0helpful
2answers

EM 220X generator (140 engine)...

Adjustment screw for the governor which is directly related to the engine speed
10/14/2017 12:23:27 PM • Honda Electrical... • Answered on Oct 14, 2017 • 315 views
0helpful
1answer

Cant figure out how to get the choke spring on my honda eu3000is generator. i acn get it to close but spring wont push it open

At about the 35minute mark in this hour + video there are pictures of your carb setup. Maybe it will help - Auto choke for Honda EU3000iS by Pinellas Power Products
10/11/2017 10:14:21 PM • Honda Electrical... • Answered on Oct 11, 2017 • 1,804 views
0helpful
1answer

Ex 5000 sx generator, no power

Hello dear, would you consider buying a new generator? Generator Diesel Generator Cummins Generator Volvo Generator Perkins... If you can start your generator normally, you can analyze the reasons through the following article: Why Diesel Generator Fail to Start Simple Ways to Deal with Diesel Generator Failure Hope it works for you.
9/22/2017 2:39:37 AM • Honda Electrical... • Answered on Sep 22, 2017 • 237 views
0helpful
1answer

Honda generator eb4000x gfic tripping

if you are using a lead that has a active , a neutral and a ground wire in the lead , there is no real reason to ground the gen set itself the neutral will not be bonded to the frame as that would create a possible short during operation the circuit is simple --active is the power wire --neutral is the return wire from the applications and the ground wire is for dead shorts and to prevent electrocution
9/9/2017 9:39:36 AM • Honda Electrical... • Answered on Sep 09, 2017 • 670 views
0helpful
1answer

How do I remove the gas tank from a Honda 3000 generator

undo the fuel line and the mounting bolts and slide it out from under the frame
6/30/2017 9:57:30 PM • Honda Electrical... • Answered on Jun 30, 2017 • 1,627 views
0helpful
1answer

Honda GX390 Generator not performing under load.

a GX390 Honda Motor but the used generator stator can be different cannot give more suggestions then measuring the circuitbreaker it can be broken the suggestion 60 mf capacitor can have trouble and electronic modul and bridge rectifier for some other dc connectors the coil diodes inside the stator. several options to go.
6/21/2017 5:53:12 PM • Honda Electrical... • Answered on Jun 21, 2017 • 570 views
Not finding what you are looking for?
Honda 1986 Trx200 Sx Fourtrax 200sx 87 Generator Flywheel With Starter Clutch Logo

3 questions posted

Ask a Question

Usually answered in minutes!

Top Honda Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...