Honda outboard - Page 9 - Answered Questions & Fixed issues

0helpful
1answer

Carburetor buterfly actuator tension spring for chinese honda motor

this is known to be a throttle return spring any honda dealer should have them or try equipment rental places if you like the part number i can add it do not have it at the moment .
9/3/2014 12:55:59 AM • Honda Electrical... • Answered on Sep 03, 2014 • 155 views
0helpful
1answer

Honda gx240 runs with choke on but when off it surges and I cannot get it to run smooth?

clean carburetor fuel jet and tube located inside the stem of carburetor removal of fuel bowl is recommended the bolt is a 10 mm and the same bolt screws into the stem where the jets are located,make sure all the holes are clear re install.
9/3/2014 12:52:02 AM • Honda Electrical... • Answered on Sep 03, 2014 • 1,584 views
0helpful
1answer

Why does my honda gx240 generator not stay running?

check oil level you should have it up to the first thread of filler hole without it over spilling if so drain to proper level if oil is contaminated with fuel and over filled your carburetor float may be stuck open,if so have the carburetor cleaned or serviced or you can try and clean it yourself.give me an update of your status,honda tech for 30 years
9/3/2014 12:23:32 AM • Honda Electrical... • Answered on Sep 03, 2014 • 518 views
0helpful
1answer

Service centers in philippines

Yep - try the muffler from a Subaru or other small car.
7/27/2014 3:08:54 AM • Honda Electrical... • Answered on Jul 27, 2014 • 57 views
0helpful
1answer

How many kva has a 3 phase 10.5kw generator?

About 10.5. One KVA just about equals one kilowatt, because one VA just about equals one watt. Not exactly, under all conditions, but it's pretty close for most purposes.
7/27/2014 2:37:57 AM • Honda Electrical... • Answered on Jul 27, 2014 • 134 views
0helpful
1answer

Why my honda 2000 generator will not work with surge guard with transfer switch. model 40250

Are you using a 4 conductor cable from your generator to your transfer switch? Or is it a 3 conductor cable? If it is a 3 conductor cable then try jumping the neutral to ground in the plug of the cord. Good luck, Marty
7/17/2014 8:13:43 PM • Honda Electrical... • Answered on Jul 17, 2014 • 95 views
0helpful
1answer

Why honda generator engine oil become dark quickly

does the engine rotate easy I was thinking that maybe you overtightened the Rod to the Crank.
5/29/2014 11:06:42 PM • Honda Electrical... • Answered on May 29, 2014 • 73 views
0helpful
1answer

How do i remove the starter on a Honda ES6500 generator

Remove ground wire from battery post. Make sure unit is off too. Remove start wire and cable from starter and both bolts. Reinstall in reverse order.
5/25/2014 10:17:10 PM • Honda Electrical... • Answered on May 25, 2014 • 1,594 views
0helpful
1answer

I have an older honda ex 1000 that just will not charge,

When you say "can't get to charge" are you talking about the low ac voltage coming out or receptacles or what?
5/25/2014 10:13:37 PM • Honda Electrical... • Answered on May 25, 2014 • 232 views
0helpful
1answer

What would cause a Honda Generator not to stay idled up?

There's 2 possible causes . I believe there's a service bulletin from American Honda to replace the small electric motor on top of the carburetor , if still under warranty you good if not have your local dealer contact tech line for a good will warranty . 2nd cause is the inverter behind the front panel . The inverter controls spark , idle and all of the electronic and electric components on your generator . Hope this helps
5/18/2014 11:32:55 PM • Honda Electrical... • Answered on May 18, 2014 • 187 views
0helpful
1answer

Service manual honda gx340

HONDA GX340 GX340K1 ENGINE SERVICE REPAIR PDF MANUAL DOWNLOAD 1991-2001 HONDA GX340 GX340K1 ENGINE SERVICE REPAIR PDF MANUAL DOWNLOAD 1991 2001... YOU CAN GET THAT REPAIR DONE TODAY! EVERY SERVICE AND REPAIR JOB IS COVERED! CLICK ON THE DOWNLOAD NOW BUTTON! FACTORY TYPE PDF SERVICE REPAIR MANUAL! With this Professional Quality, highly detailed Service Repair Workshop Manual you will be able to work on your vehicle with the absolute best resources available, which will save you a lot of money in repair costs and will also help you to look after your vehicle. Contains step by step instruction & highly detailed exploded pictures & diagrams to show you how to complete the required job correctly & efficiently. Covers the entire vehicle from front to back, its the same type of Manual that is used by Professional Mechanics to service or repair your vehicle. ** An absolute wealth on information at your fingertips! ** This manual is very easy to use! ** Print what you need when you need it! ** The ONLY Service Repair Workshop Manual You Will Ever Need! ** All repair procedures are covered! ** PC & MAC Compatible PDF Instant Download means there is NO shipping costs or waiting for a CD or paper manual to arrive in the mail! You will receive this manual TODAY via Instant Download.
4/14/2014 9:35:31 PM • Honda Electrical... • Answered on Apr 14, 2014 • 1,344 views
0helpful
1answer

Cannot get my generator to run on 220 mode, only runs on 110 when I disengage the auto throttle

There's a short in the 220 circuitry. Check for continuity between the two hot leads, or between the hot leads to ground I’m happy to help further over the phone at https://www.6ya.com/expert/robert_24775b73ca70da93
1/27/2014 10:19:49 AM • Honda Electrical... • Answered on Jan 27, 2014 • 120 views
0helpful
1answer

11hp honda carb floods

Sounds like the Float is either broken so it doesn't float and shut off the Needle Valve. More likely the carburetor is gummed up from a few month old ethanol gas and the Needle valve is stuck. Write your Congressman and tell him to get rid of the Ethanol Gas law that is up for vote again. Ethanol is killing carburetors
12/15/2013 7:10:50 PM • Honda Electrical... • Answered on Dec 15, 2013 • 164 views
0helpful
1answer

Eb7000 won't stay running after 12 seconds disconnected the oil sensor wire but no change

Check rotor slip rings for tarnish, gen control needs to sense stator voltage is produced
11/17/2013 4:47:45 PM • Honda Electrical... • Answered on Nov 17, 2013 • 147 views
0helpful
1answer

Power Automatic low then balnce

Do you have other loads pulling the voltage down, compressors in airconditioning, motors, etc. Perhaps when you measure voltage at 230V which should not cause a issue it's within 10%. But maybe a motor pulls in and drops it further than you measured? Re-check with meter and record. Check generator for overloading and also wiring size feeding
11/17/2013 4:18:31 PM • Honda Electrical... • Answered on Nov 17, 2013 • 49 views
0helpful
1answer

Honda iGX 440 smokes at initial start up and burns

Yes the exhaust valves can be burnt, however is there any pressure in the crankcase when you do the leakdown test? Ex valves normally cause lack of compression and not oil burning. If rings are worn also then you will see pressure in the crank case
11/17/2013 4:10:29 PM • Honda Electrical... • Answered on Nov 17, 2013 • 260 views
0helpful
1answer

Faltering with a load. Runs fine without a load.

check carburettor main jet
11/4/2013 1:21:52 AM • Honda Electrical... • Answered on Nov 04, 2013 • 64 views
0helpful
1answer

Generator is consuming more mobile due to worn out

mobile ? what ? fuel / oil ?
11/4/2013 1:06:42 AM • Honda Electrical... • Answered on Nov 04, 2013 • 32 views
0helpful
1answer

What is the standard length of the starter rope on

probably 3 feet
11/6/2013 10:12:51 AM • Honda Electrical... • Answered on Nov 06, 2013 • 1,343 views
0helpful
1answer

More a question than problem. should i run my

It depends on how long until you plan to use it again.How long you can leave gasoline in your fuel tank without risking problems varies with the blend of gasoline, the room temperature and even how much of the tank is filled. Air and warm temperatures cause faster fuel deterioration, which lead to hard starting. You should be okay for a about 3 weeks in most cases (maybe more if you use stabilizer), but if you will not use the generator for longer than that, you should drain the carburetor, sediment cup, and fuel tank to avoid fuel deterioration problems.Your owner's manual should include a table with the storage times and recommended draining/service. If you don't have your manual, you can find most of them online, all you will need is the brand and model of your generator.
10/29/2013 7:33:56 PM • Honda Electrical... • Answered on Oct 29, 2013 • 94 views
Not finding what you are looking for?
Honda outboard Logo

11 questions posted

Ask a Question

Usually answered in minutes!

Top Honda Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides