Top 20 Honda Snowblower Cover Silver Hs928, Hs1132 Questions & Answers

1helpful
1answer

Auger clutch lever disengages even though drive clutch lever is squeezed

On mine (Honda HS55) it turned out to be gummy old grease on the shaft and the lever that are supposed to lock the auger lever down. The spring couldn't overpower the sticky old grease. If nudged or given enough time, it would slowly turn and lock, but not instantaneously, as it should. 10 mm wrench to remove the nut (bottom left) and bolt (under handle) holding on the metal cover. Once cover was off I could see the locking lever, spring, and the shaft that had the gummy grease on it. The third photo shows the locking lever as it should be engaged. I had to push it to engage it, due to the spring not being strong enough for the gummy grease on the shaft. There are flat sides on the shaft, behind the threads for the nut that has already been removed. Use a wrench on those to turn the shaft out. Disassemble. Clean. Oil. Reassemble. Works great now. Another possibility is that your locking lever or spring are broken. 1_zps7a4241d0.jpg 2_zps266fe5e3.jpg 5_zpsb996522b.jpg 6_zps6ca7f90a.jpg
12/17/2013 10:53:17 PM • Honda Snowblower... • 3,099 views • 1 helpful votes
0helpful
1answer

How to remove tank on a honda eg5000cl generator

This is reasonably easy to do. Does the Generator run? Start the generator as it's running turn the fuel Petcock to the Off position. The generator should stall and stop running. This helps safely empty the fuel line and carburettor between the tank and the engine. Disconnect the fuel line from the petcock tap and plug the ends to stop dirt getting in. On each corner of the tank itself there should be a bolt going through the ribbed edge and a rubber spacer. remove these 4 bolts and the tank should lift up and out. On some generators you might have to remove some trim panels to make it easier. Refitting is the exact opposite of this.
1/28/2024 4:49:26 PM • Honda Electrical... • 29 views • 0 helpful votes
1helpful
1answer

Honda2200 generator, bluetooth

Provides information about the generator's status, performance, and reminders. The app also allows you to turn the generator on and off remotely, monitor fuel levels, and set the Eco-Throttle mode. Connect Your Honda 2200i to Bluetooth - YouTube honda 2200 bluetooth pairing - Search (bing.com)
1/21/2024 10:30:21 PM • Honda Electrical... • 29 views • 1 helpful votes
0helpful
2answers

Hi does anyone know or have a contact for parts for a Honda eg550 generator

You'll need allot of info from your unit...but ck here...https://www.megazip.net/zapchasti-dlya-generatorov/honda/eg550-12536/eg550-25744or try here...copy and paste.https://www.megazip.net/zapchasti-dlya-generatorov/honda/eg550-12536/eg550-25744/eg550-770365/fuel-tank-eg550-eg650-13411092
7/14/2023 9:36:41 PM • Honda Electrical... • 34 views • 0 helpful votes
0helpful
1answer

Honda EX5500 power output

It sounds like you are experiencing an issue with your ex5500 generator where the voltage and frequency are not within the correct range when the generator is running. Here are a few steps you can try to troubleshoot the issue:
  1. Check the load: Make sure that the load you are running on the generator is within its capacity. If the load is too high, it can cause the generator to run at a lower frequency and higher voltage.
  2. Check the fuel level: Make sure the fuel tank is full and that the fuel is fresh. If the fuel is stale or contaminated, it can cause the generator to run poorly.
  3. Check the spark plug: The spark plug is responsible for igniting the fuel in the engine. If the spark plug is dirty or worn out, it can cause the generator to run poorly. Clean or replace the spark plug as needed.
  4. Check the air filter: The air filter is responsible for cleaning the air that is drawn into the engine. If the air filter is dirty or clogged, it can restrict the flow of air to the engine and cause it to run poorly. Clean or replace the air filter as needed.
If none of these steps help resolve the issue, it may be necessary to have the generator checked by a professional. They can diagnose and repair any underlying issues that may be causing the generator to run poorly.
12/11/2022 7:31:38 PM • Honda Electrical... • 103 views • 0 helpful votes
0helpful
1answer

On a Honda eu2000 generator. Generator will start then shuts off because overload light comes on

check outlets and wiring for corrosion or short
11/30/2022 4:15:45 PM • Honda Electrical... • 74 views • 0 helpful votes
1helpful
1answer

I've a Honda eu3000is generator, new carb, new starter. It will electric crank but not start but I can pull start it.

it seems like your ignition switch may not be removing the ground while in the starting position try removing the ground wire from key switch if it turns over and start with key replace switch assy.
10/8/2022 10:48:48 PM • Honda Electrical... • 245 views • 1 helpful votes
1helpful
1answer

Honda em5000sx generator runs too fast

it's possible that u may have a worn washer underneath the governor gear it's internal this washer wears due to lack of oil change 4800 is way too high for that engine to operate 38oo max parts are inexpensive although doing the job to repair it is another it's behind the front cover of engine you need washer slider and governor gear totl cost of parts under 30.00.
10/15/2022 4:50:59 AM • Honda Electrical... • 89 views • 1 helpful votes
0helpful
2answers

Why won't my portable generator start?

Hi, if it was a copy-cat item, it might have been built with cheap parts. Please purchase the real item and you should not have these problems. I would also advise against trying to change a generator's parts because if you mess up, you could accidentally spray carbon-monoxide into your environment which can be deadly. Thank you.
10/11/2022 3:47:47 PM • Honda Electrical... • 57 views • 0 helpful votes
0helpful
1answer

Code 08 in generator honda EM7000 IS What does mean?

Go to this site and down load a manual.
9/27/2022 11:53:12 PM • Honda Electrical... • 54 views • 0 helpful votes
0helpful
1answer

Honda EG1400X generator produces power but after a short time smoke comes out of generator, seems like rotor is overheating. Is this an AVR problem?

There is a short circuit in your stator or rotor coils wires, coil wire insulation broken down, Try to get the stator or rotor rewired or replaced.
7/6/2022 5:08:13 PM • Honda Electrical... • 122 views • 0 helpful votes
0helpful
1answer

Honda SUA 2300 generator surges at idle.

It probably has bad fuel that is a few years old. Check out the videos in the link. What causes a generator to surge at idle? Surging caused by fuel problems usually happens for one of three reasons: incorrect fuel, low fuel levels, or poor fuel quality. Most generators have specific fuel requirements and using any type of fuel outside of those parameters can cause operational issues, including surges. https://www.google.com/search?q=Honda+SUA+2300+generator+surges+at+idle ..
4/28/2022 2:52:45 PM • Honda Electrical... • 184 views • 0 helpful votes
0helpful
1answer

Honda generator eu6500is overload

if you mean the gas engine starts and then dies, its not getting fuel fast enough, a screen or filter, if its the type you start then engage the generator and it dies, not sure,, also a lot them have an oil sensor,, the older ones went bad a lot..., the all go bad eventually, most of the time you can unplug them and it will run fine,,, the wire that is connected near the bottom of the crankcase and usually has a plastic plug within a couple inches, just unplug it and see if that fixes it.... those new sensors shouldn't be very expensive. those are the two top issues....plugged up fuel supply in the carb or the screen in the tank or a filter in between,, or the oil sensor is bad... the sensor idea is because you're inside the house and the generator is outside so you wont notice if it runs low on oil and the sensor will shut it off to save it from damage...
11/21/2021 1:21:18 AM • Honda Electrical... • 368 views • 0 helpful votes
0helpful
2answers

Why won't my honda generator won't produce electricity but runs

Have you checked all your fuses and switches?
11/2/2021 6:08:39 PM • Honda Electrical... • 205 views • 0 helpful votes
0helpful
1answer

Have no output power on my pramac s5000 . Motor starts fine, flip CBS on, and motor surges a second.

Disconnect all loads before turning on breaker. Add one load at a time. Do not exceed generator capacity.

Comment below for further assistance.
6/16/2021 9:08:52 PM • Honda Electrical... • 208 views • 0 helpful votes
0helpful
1answer

Honda generator EU65is. The overload indicator light will not shut off. Why?

It would normally show that you are drawing more power than the generator can supply. Videos in the link https://www.google.com/search?q=Honda+generator+EU65is+overload+indicator ..
4/18/2021 2:34:23 PM • Honda Electrical... • 634 views • 0 helpful votes
0helpful
3answers

I have a gas generator a Honda and someone put 2cycle feul in it now it starts and runs for 20 to 30 minutes and. Stops it displays trouble code E-0A

The error code is for incorrect air/fuel ratio. The first thing to try and most common cause is a bad fuel filter. Try replacing the fuel filter. It is possible that the 2 cycle mix, since it contains oil, had gummed up the filter. I would also run some carburetor cleaner through it.
11/27/2020 2:42:03 AM • Honda Electrical... • 93 views • 0 helpful votes
0helpful
2answers

No Spark On Ems 4500 Honda Generator

Check oil alert switch, ignition switch and connections.
12/29/2019 11:40:54 PM • Honda Electrical... • 362 views • 0 helpful votes
0helpful
1answer

HONDA EM650 Generator starts but wont power anything up

For your question, i have replied many people, why generator set can start but not generate electricity? Here is some reasons for reference: 1.After the diesel generator is stopped, the residual magnetism is often lost, because the material used for the magnetic pole of the exciter is close to the soft steel, and the residual magnetism is small. After the shutdown, when there is no current in the excitation winding, the magnetic field will disappear. 2.The magnetic pole of the diesel generator loses its magnetic properties. 3.Damage of excitation circuit components or circuit breakage, short circuit or grounding phenomena. 4.The exciter brush is not in good contact with the commutator and pressure of brush holder is insufficient. 5.Excitation winding wiring error, opposite polarity. 6.Stator winding and rotor winding of generator set open circuit. 7.Poor contact between diesel generator brush and slip ring, or insufficient brush pressure. 8.Diesel generator lead wire wiring is loose or switch contact is poor. 9.The fuse box is fused. 10.The "auto-manual-de-excitation" switch on the control panel is in the de-excitation position (automatic generator set has "auto-manual-de-excitation" switch). 11.The voltmeter is damaged. 12.Rotary rectifier module is damaged.
10/1/2019 5:07:35 AM • Honda Electrical... • 561 views • 0 helpful votes
0helpful
1answer

Honda 8750 blackmax no electricity

If you need more support, we recommend you a support website, you can search your answer on the website: www.dieselgeneratortech.com
10/14/2019 7:00:53 PM • Honda Electrical... • 202 views • 0 helpful votes
Not finding what you are looking for?
Honda Snowblower Cover Silver Hs928, Hs1132 Logo

11 questions posted

Ask a Question

Usually answered in minutes!

Top Honda Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others

Answer questions