20 Most Recent Kohler 30rz82 30kw Generator Power System Fast Response Nat Gas 890 Hours - Page 4 Questions & Answers

0helpful
1answer

What do I need to check to activate starter will not engage. Engine will start but dies when blades are engaged

If your mower runs fine, but dies when the blades are engaged, that has nothing at all to do with the starter - or with the engine. There is a malfunction is in either the electrical system, PTO clutch or one of the safety features somewhere. Check all of the belts first for wear or breakage, then if they're OK, you probably need a small engine mechanic, but it doesn't sound really serious.
7/3/2017 1:38:28 PM • Kohler... • Answered on Jul 03, 2017
0helpful
1answer

I have a kohler 4500 watt generator in my 1992 motorhome. starts up and runs fine with the local start switch, but when i use the remote switch, it cranks and doesn't fire.

the remote has separate starting system check the unit it could be the magnetic switch. manual start bypasses this
6/21/2017 10:07:26 PM • Kohler... • Answered on Jun 21, 2017
0helpful
1answer

I have a 5000 watt marine generator .Built In the

first I would check is the low oil sensor circuit they can fail or they work best when the oil is low
5/5/2017 6:28:02 AM • Kohler... • Answered on May 05, 2017
0helpful
1answer

2oo2 kohler is not getting gas

Does this machine have a fuel filter if so make sure it's clean. Does it have a fuel bowl? Take it off and clean it out real good . also clean the fuel jet. These are why the engines do not start or run properly if one of these are dirty. Dirt keeps the fuel out of the carb.
4/16/2017 5:36:39 PM • Kohler... • Answered on Apr 16, 2017
0helpful
1answer

Kohler generator runs but no water flow. No suction or lost prime

go over board and check that the inlet end for the pump is not blocked with plastic sheeting or debris
4/14/2017 8:28:21 AM • Kohler... • Answered on Apr 14, 2017
0helpful
1answer

My 20kW Kohler home generator (nat gas) cranks but won't start. Definitely getting fuel. Everything checked in October with new spark plug. Maybe a setting?

Did you check the oil level? Some generators have a oil sensor that will now allow it to start if the oil level is too low.
3/14/2017 1:43:11 AM • Kohler... • Answered on Mar 14, 2017
0helpful
1answer

Lincoln ranger 8 and kohler engine command 20. engine does not pull gas to carburetor. Putting little gas directly in carburetor; machine runs until finish gasoline inside carburator.

engines don't "pull" fuel to carb , it either gravity flows (tank over top carb) there or its pumped there , I do believe the kohler engines from 8 hp thru 25 hp use a vacuum activated fuel pump (three hoses on it) these do go bad over time and need replaced , also there are fuel filters on all these engines that need to be replaced seasonally they are not cleanable there disposable
12/19/2016 10:20:05 PM • Kohler... • Answered on Dec 19, 2016
0helpful
1answer

Kohler not running after warmed up.

IMPORTANT replace in first priority the sparkplug (control the oil level) tankairiation if not cured The ignition coil can be thermical damaged, (try coldspray to test on it ) if ordering have high priorty on motornumber and year of build by your model to prevent there are no marketing technical upgrade/ modifications are made because then you get no spark to see either, if get the wrong for the different flywheel
11/2/2016 12:36:43 PM • Kohler... • Answered on Nov 02, 2016
0helpful
2answers

I have a 7kw Kohler marine generator that shuts of when boat gets up on plane New impeller New fuel filter I started it runs for a while then shuts off It takes a bit to start but runs for 20 plus hrs

I take it that this unit runs the power on board and is permanently fixed in the boat you mention new impeller so logically that means that it is water cooled drawing the cooling water from outside (underneath the boat) pursuing logic further if that is the case then there is a shut down circuit for the water flow to prevent overheating should the water inlet become blocked ( weeds, plastic cloth etc) from your question and statement I would be looking in that area to make sure water flow is not restricted or the protection circuit is operational ( no corrosion in terminals and wires )
10/1/2016 1:24:28 AM • Kohler... • Answered on Oct 01, 2016
0helpful
1answer

I have a Kohler 7.3 ECD generator with error code UVunder frequency. Restarted gen and it ran for one hour so I shut it off. What's the problem?

check the operating rpms the rpms determine the voltage and frequency and can be adjusted at the governor spring setting adjust it until the voltmeter reads the required voltage set slightly above to allow for rpms drop under load for example if 240 volts set around 250 volts and that will drop back to 240 volts under load if 110 set around 115 and that will drop back under full load both frequency and volts are dependant on rpms
9/21/2016 1:29:50 AM • Kohler... • Answered on Sep 21, 2016
0helpful
1answer
0helpful
1answer

Gen set blows fuse

no a fuse is there to protect the circuit and the genset check why the de-icer is pulling so many amps as the problem may be in that unit a 10 amp outlet has a maximum current capacity of 10 amps as that is the current allowable from the gen set and wire capacity even if you had an outlet with 15 amp rating , it would still be blowing fuses as the 16 amps is above the allowable current draw you would need a 20 amp outlet ( difficult to get unless it is in a house power board and are normally reserved for hot water systems , stoves and other high current usage units and are normally then not outlets but hard wired in to a circuit breaker
8/10/2016 11:36:37 PM • Kohler... • Answered on Aug 10, 2016
Not finding what you are looking for?
Kohler 30rz82 30kw Generator Power System Fast Response Nat Gas 890 Hours Logo

1 questions posted

Ask a Question

Usually answered in minutes!

Top Kohler Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66827 Answers

Are you a Kohler Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Kohler Electrical Supplies

  • Kohler Electrical Supplies

Most Popular Question

cylinder head torque specs 23 horse

  • Electrical Supplies
Loading...