Frozen the coil and leaking water
Turn it off, let the coil defrost completely. After the dripping has stopped completely, check to see that paper and dirt is cleared from the air inlet side of the evaporator. Put a red stick thermometer inside the cooler and don't let the temperature go below 37 degrees F. Make sure the condenser is clean, the door gaskets are good and the doors are closing properly. Last thing is its low on gas and needs a service call. Good luck hope this helps.