Its frozen and cannot load
It is power supply regulator problem.
In the regulator circuit, DC 12volt from adapter is separated into +8V, -8V, +5VA, +5VD'
Some causes when the unit hang / frozen is one of the existing supply voltage is drop. In general, +5V.
Also check the adapter voltage, if still normal and the current is sufficient. Adapter must have DC12volt and current of at least 3 amperes.
It may happen, when the adapter is measured without load, it's read normal,12v. But when loaded to turn on the keyboard, many voltage decreases (lets say,between 8-10v). This indicates that the adapter is not good.
Hi i got the korg
NOT a fuse... thaat person knows nothing. There is something wrong for sure. Check if one of the buttons or keys MIGHT be stuck down (depressed). Sometimes the units check that all the control buttons are up and they don't really tell you why they fail to start. Beyond this a repair shop is in order.
My korg m50 audio output R-L MONO VOLUME OUT IS TOO LOW
Might be a case of opening up the M50 as the previous poster did and wiggle connectors and components until the sound is affected. If you have some electronics experience, it should be fairly easy to figure out which board to investigate.