Sensor remote does not send
After some time outside, corrosion occurs on the circuit board, when water enters the unit through the vent on the front of the sensor. The vent should not be blocked, as this will still result in corrosion due to condensation building up in the sensor. Corrosion will be less likely to occur, if the sensor is located away sources of humidity and falling water. I located mine in the shade on my deck, under an upsidedown flower pot.
12/5/2010 11:38:04 PM •
La Crosse...
•
2,212 views • 3 helpful votes
What does OF.L mean in display?
It means OverFLow - the display unit can read from -39.8°F to 139.8 °F and it is getting a signal from the sending unit that is lower than -39.8 or higher than 139.8. This happens when the sending unit goes haywire (or, not likely, when temperature out doors is REALLY lower or higher than the range). Replace the sending unit. If you really like the product, I suggest you buy another of the same model. It will come with a new sending unit and that will be read by both of the displays if they are within 80 ft of the sending unit. Good luck.
10/19/2014 3:34:36 PM •
La Crosse...
•
366 views • 0 helpful votes