20 Most Recent Raypak 2100 Pool Heater Gas 266000 BTU' (Pilot Light) () Questions & Answers

0answers
0helpful
1answer

What is a POL code on Raypak 2100 heater?

sounds like it needs a new pilot generator
10/15/2014 1:22:05 AM • Raypak 2100 Pool... • Answered on Oct 15, 2014
0helpful
1answer

Why does Heater keep shutting off and on. Tech says everything looks ok by milli volt readings

problem is you either have a poor neutral connection, one of the safeties is opening and closing at times, or the gas valve is faulty
7/3/2014 10:35:42 PM • Raypak 2100 Pool... • Answered on Jul 03, 2014
0helpful
1answer

What is a high limit condition

temp sensor failure. when sensor read temps that are way too cold or way too hot
5/10/2014 12:46:45 AM • Raypak 2100 Pool... • Answered on May 10, 2014
0helpful
1answer

Ilo display when trying to

ignition lockout. heater has tried to fire up 3 times without success. after three attempts unit will temporarily lock itself out