Walking belt slip, sliding away!

You need to replaced the walking belt and have a professional reset the drive belt to the proper tension.
8/2/2017 6:00:40 PM • HEALTHRIDER... • Answered on Aug 02, 2017 • 157 views
0helpful
2answers

I have a 300I health

DEAR IF YOUR TREADMILL IS OLD AND YOUR WEIGHT IS MORE THAN 80 YOUR MOTOR TREADMILL IS WEAK NOW AND MUST BE REPLACE IT ONLY . you can countiue contact us with smart phone on wattsapp or telegram by : +989195116738
4/18/2017 1:35:26 PM • HEALTHRIDER... • Answered on Apr 18, 2017 • 236 views
0helpful
1answer

What could the problem be for this? Have a treadmill that's been outside for a while. The cord was chewed up and I have replaced it, but it goes on for a couple seconds then turns off. What could the

If it was outside, was it under cover? If it was not, then the console circuitry are corroded and not fully up to themselves. If it was under cover, same thing can happen. temperature and humidity, moisture and cold can also impair the performance of the unit. It may be a difficult problem to trace unless you can open the console and see for yourself the state of the printed circuit board/s. If it looks like silvery powder around the IC's (integrated circuits) pins, then tht's some air and moisture damage. If you live by the sea, same thing will happen on appliances left outside. And to find the cable chewed, looks like it's been outside for a long time and may definitely have rust on the circuit board, in other words - moisture damaged. If there is no silver rust (powdered ash-type rust) and the printed circuit board looks clean, then try and locate the treadmill manufacturer or its supplier websites and email them the problem you're having.
8/1/2014 4:00:30 PM • HEALTHRIDER... • Answered on Aug 01, 2014 • 95 views
0helpful
1answer

Belt slips

please see the video and proceed according. God bless you
11/28/2013 10:48:58 AM • HEALTHRIDER... • Answered on Nov 28, 2013 • 84 views
0helpful
1answer

Controller what is the voltages output on a

the voltage controller is the same for input voltage terminal of the motor .test the input voltage terminal motor, if there ARE not the motor is faulty.Read my personal TIPS motor2) test the output voltage control board, if there ARE not the control board is faultyGod bless you
10/22/2013 12:27:49 PM • HEALTHRIDER... • Answered on Oct 22, 2013 • 155 views
0helpful
1answer

How do you know if its the motor control board or the motor

1) test the voltage input motor, if there are voltage the motor NEED repair2) test the output voltage board, for input voltage motor, if there are NOT voltage , the board is faulty.see my personal TIPS, very important.God bless you10_17_2012_12_40_43_pm.gif
10/17/2012 12:40:47 PM • HEALTHRIDER... • Answered on Oct 17, 2012 • 357 views
0helpful
1answer

HOW TO CLEAR MEMORY

for waht reason do you need clear the memory? in treadmills. Normally you do not need to do that. Please what is the reason, and will reply .God bless you
7/17/2012 10:36:07 AM • HEALTHRIDER... • Answered on Jul 17, 2012 • 106 views
0helpful
1answer

HOW TO CLEAR THE ELECTRONICS

Call Treadmill Doctor at 800-750-4766 and they will walk you thru the steps needed to clear the board
7/16/2012 4:00:20 PM • HEALTHRIDER... • Answered on Jul 16, 2012 • 124 views
0helpful
1answer

Although the unit powers up

1)see if the breaker is tripped2) tight the flexible cord from keypanel vs display board3)tight the connector display board vs lower board4)see the main motor board is working if the signal is coming by 5vdc5) main motor faulty repair.see block diagram
12/13/2011 9:36:27 PM • HEALTHRIDER... • Answered on Dec 13, 2011 • 393 views
0helpful
1answer

My son folded my healthrider s300i while it was in

1)tight the flexible cord from key panel vs display board2) tight the display connector vs lower board3) test the main motor board 4)motor burn to worn deck belt5) adjust the pot in the elevation motor6) gear is slipping repair.sincerely
12/13/2011 9:32:35 PM • HEALTHRIDER... • Answered on Dec 13, 2011 • 550 views
0helpful
1answer

I have a Healthrider Softstrider

1) you have 3 problems: mechanical+ electrical + electronic.2) adjust the tensions from deck bel + drive belt motor3)test the main motor without load and see what happen.4)test the main motor board and see what happen.see block diagram12_13_2011_9_28_47_pm.gif
12/13/2011 9:29:16 PM • HEALTHRIDER... • Answered on Dec 13, 2011 • 594 views
0helpful
1answer

The incline on my HEALTHRIDER

1) tight the flexible cord from keypanel vs display board2)tight the display board vs lower board(main motor board)3)Test the main motor board(faulty to worn deck belt)4)INCLINATION motor burn.5)Adjust Pot from the inclination motor6) the gear slip adjust or repair.see the block diagram12_13_2011_9_24_50_pm.gif
12/13/2011 9:25:21 PM • HEALTHRIDER... • Answered on Dec 13, 2011 • 896 views
0helpful
1answer

Healthrider will turn on and

1) IF THE MACHINE ONLY RUN IN DEMO MODE, TRY TO RUN IN NORMAL POSITION.2)PUSH AND HOLD ON THE STOP BUTTON BY 5 SECONDS.3) IF THE PROBLEM PERSIST, TRY TO TIGHT THE FLEXIBLE CORD FROM KEY PANEL VS DISPLAY BOARD.4)TIGHT THE DISPLAY BOARD VS LOWE BOARD(MAIN MOTOR BOARD)5) IF THE PROBLEM PERSIST THE MAIN MOTOR CONTROLLER BOARD IS PROBABLY FAULTY.6)bEFORE TEST THE MAIN MOTOR.SINCERELY.12_13_2011_9_19_40_pm.gifSeethe block diagram
12/13/2011 9:20:19 PM • HEALTHRIDER... • Answered on Dec 13, 2011 • 377 views
0helpful
1answer

My healthrider s300i softstrider treadmill

1)See if flexible cable from display board is bending to lower board.2)main motor board is faulty by worn deck belt.3) burn motor faulty.4) adjust the Potentionmeter from the motor (incline).5)Defective gear in inclination motor.See the block diagram12_13_2011_9_11_38_pm.gif
12/13/2011 9:12:01 PM • HEALTHRIDER... • Answered on Dec 13, 2011 • 665 views
0helpful
1answer

I can't fold my treadmill

1) SEE IF SOMETHING IS PENDING between the folding section2) Your Pin is little bend.3) the receiver where the pin is coming is not adjusted.sincerely.
12/13/2011 9:07:08 PM • HEALTHRIDER... • Answered on Dec 13, 2011 • 2,385 views
0helpful
1answer

Where can I buy the motor control board for the spirit treadmill z-500?

you can buy in fixya.comwww.fitnessrepairparts.comwww.gymparts.comwww.treadmilldoctor.comsincerely
12/13/2011 9:03:08 PM • HEALTHRIDER... • Answered on Dec 13, 2011 • 158 views
0helpful
1answer

I have a HealthRider S300i

you can try to rent a set at AutoZone. when you return it they will give your money back. try standard and metric. depending on manufacturer of treadmill.
2/9/2011 2:31:44 AM • HEALTHRIDER... • Answered on Feb 09, 2011 • 411 views
0helpful
2answers

Motor runs, but speed control

Hi, press the Stop and the Speed Up keys down while inserting the safety key this will get the into calibration mode. The next step is to press the Stop key one time. The Time window should read EP:2P. Some newer models may also say FP, Pass, or the like. This means that it passes the EPROM test. if it says 2F, FF or Fail then the upper console needs to be replaced
Press either incline key and the incline will calibrate automatically.
BE CAREFUL, THE TREADMILL WILL RUN AT FULL SPEED IN THIS NEXT MODE! DO NOT STAND ON THE WALKING BELT. Press the Speed Up key and hold it down until 85 is shown in the Distance window (some models may show the 85 number in another window
If the belt does not move in this mode then the controller board is defective and needs be replace.
1/22/2011 12:31:33 PM • HEALTHRIDER... • Answered on Jan 22, 2011 • 352 views
0helpful
1answer

I Have a healthrider softrider

Hi,

This due the belt is loose problem.Here is the maintenance manual for your more help.

http://www.fitness-equipment.com/Manuals/Healthrider-Manuals/299300.pdf

Please do rate the solution if the issue is resolved or post a comment for further assistance.


Thank you for using fixya have a nice day:-)
1/22/2011 2:06:38 AM • HEALTHRIDER... • Answered on Jan 22, 2011 • 570 views
0helpful
1answer

My ten year old Health

First be sure there is power at the outlet. Check that the power switch is on, and the circuit breaker is not tripped (beside the power cord).
Remove the hood and inspect the wiring. (unplug the machine first). Ensure that all connectors are tight and none are burnt. At this point if all appears to be OK, look for lighted LEDs on the power PCB. If all is dark, replace the power PCB ( approx $100). If the LEDs are lit, you may require a console, or the safety key switch might be defective. To check it, the console must be removed and the console base removed. Inspect and test the micro switch.
The console is no longer available.
12/19/2010 4:44:47 PM • HEALTHRIDER... • Answered on Dec 19, 2010 • 331 views
Not finding what you are looking for?
HEALTHRIDER S300i Treadmill Motor Control Board  14470 Logo

42 questions posted

Ask a Question

Usually answered in minutes!

Top HEALTHRIDER Exercise & Fitness Experts

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66772 Answers

ADMIN Eric
ADMIN Eric

Level 3 Expert

39345 Answers

Are you a HEALTHRIDER Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...