Precor 927 Treadmill - Page 3 - Answered Questions & Fixed issues
How to fix error code 50 on EFX 5.21i?
Precor Error 50, Too Much Brake (Magnet) Current
Probable Cause
1. Shorted or damaged wiring between the lower PCA and the eddy current magnet is the most common cause for this error.
2. Bad eddy current magnet.
3. Bad lower PCA.
Corrective Action
- Thoroughly inspect the eddy current wiring and connections ensuring that the wires are not shorted to the frame or shorted together. Repair or replace damaged wiring as necessary.
- Disconnect the wires from the eddy current magnet. Using an ohm meter, check for approximately 100 ohms across the eddy current magnet terminals. If the reading is considerably low, replace the eddy current magnet. Measure ohms between each eddy current magnet terminal and the frame ground. You should have no resistance between the eddy current magnet terminal and the frame ground. If resistance is present this would indicate a partial short, replace the eddy current magnet.
- If the eddy current magnet wiring and the eddy current magnet are both good from the above tests, replace the lower PCA.
Error 50 Too Much Brake Current on Precor Cardio Equipment
Precor C954i incline not working.
Proform Treadmill Incline Problem Fixed
pLEASE Test fo 120 vac forward and backward
2) if there are voltages coming from controller boad motor the inclination motor is fault or capacitor
3) If there are not the controller board motor is fauty
3) However are some treadmill working with relais see if this relais are coming up in the respective board, if Do not see if there some fuse faulty and replace, if there are good the board is faulty for incline motor.