0helpful
1answer

VT60 just clicks and flashes 88 when I plug it in

same thing with mine any suggestions anyone?
3/6/2023 5:51:09 PM • VinoTemp VT-60... • Answered on Mar 06, 2023
0helpful
1answer

Viking vuwc141 wine cooler not cold anymore.

dead, and PC power good to it. and not ICING up as the manual warns and why. on mine the carp's mounted it in front of web bar,and no air can get to it (called a bad INSTALLER) all Refers must have fresh are to the condenser core and so it can not cool so I slid it back 1 inch and see a gap now, top and air now flows, to back side easy (amazing easy fix) 2005 model and still works today, just 30seconds work. also same cause for the compressor overheat sensor to trip, same cause same cure. cause 2, condenser fan dead or only packed up in lint. rtm https://www.manualslib.com/products/Viking-Vuwc140-4057175.html free. bad thermostat bad power on switch. also see the complex AC control option if present. last pages.
11/25/2022 6:40:02 PM • VinoTemp VT-60... • Answered on Nov 25, 2022
0helpful
2answers

Our VT60 quit cooling. It

Check the pressures.
3/5/2018 11:47:32 PM • VinoTemp VT-60... • Answered on Mar 05, 2018
0helpful
1answer

My vt60 winw cooler doesnt cool , it will show the degrees you want to set it at then few seconds later it goes back to the room temp. of 76...also makes clicking noise to start compressor then again

Sounds like the compressor is frozen - sound you hear is the clixon a special sort of resettable fuse on compressors. When they do not start or overheat, it kills the power - when it cools power is restored until it reheats again and ....................... Use ammeter to confirm this - it will show a much greater than normal current draw.
9/1/2015 4:33:15 PM • VinoTemp VT-60... • Answered on Sep 01, 2015
0answers
0helpful
1answer

Vinotemp not staying cool, it's

Step 1:

It's most likely the PTC (Positive Temperature Compensated) start relay that turns the compressor on and off. The manufacturer has replaced part number P6R8MC with part number 6R8MG for this PTC start relay. Order part number 6R8MG, it cost less than $20.First, unplug the wine cooler and take off the back panel. The back panel is held into place with several philips head screws.

Step 2:

Locate the compressor. You'll find the compressor in the bottom left corner of the VT-60 as viewed from the back. You will see copper tubes coming out of the compressor. These tubes carry the compressed refrigerant to the evaporator assembly. Be careful not to crimp or damage the copper tubing.

Step 3:

Find the black plastic cover to the left of the compressor. This cover is held into place with one philips head screw. Remove the screw and remove the cover to find the PTC start relay.

Step 4:

The replay is connected to the compressor by a single blade connector and two pins which protrude from the compressor. Remove the blade connector and pull the PTC relay to the left, sliding it off the pins attached to the compressor.

Step 5:

Slide the relay on the connector pins, reattach the blade connector, reattach the black pastic cover over the relay, reattach the back panel onto the VT-60 and you're done.
7/26/2014 7:57:25 PM • VinoTemp VT-60... • Answered on Jul 26, 2014
0helpful
1answer

Vt200 temperature

24 hours
5/24/2014 6:27:48 PM • VinoTemp VT-60... • Answered on May 24, 2014
0helpful
1answer

Why won't my VT60 hold a temperature in the high 50's any longer? It is at 74 and won't let me change it to the 50's.

Make sure all the dust is removed from coils, fan blades and intake vent grill / filter!!! drain the condensation collection pan, and then reset the thermostat and wait 24 hours; before checking the temperature with a digital temp. gauge.
5/6/2014 3:38:50 AM • VinoTemp VT-60... • Answered on May 06, 2014
0helpful
1answer

Settings on cooler are not holding and cooler only reads room temperature

need more info - is the compressor running?
4/22/2014 9:07:13 PM • VinoTemp VT-60... • Answered on Apr 22, 2014
0helpful
1answer

Need to replace compressor on vinotemp wine coooler

Return the compressor and buy another wine cooler. This work is too complex for people that do not do this every day, Thanks Sea Breeze
11/20/2012 7:46:22 AM • VinoTemp VT-60... • Answered on Nov 20, 2012
0helpful
1answer

What does LL on vinotemp mean?

For LL error code,click the link below :----http://technoanswers.blogspot.com/2012/01/ll-error-on-vinotemp-wine-cooler.html -----------Thanks.
1/26/2012 3:02:21 PM • VinoTemp VT-60... • Answered on Jan 26, 2012
0helpful
1answer

Compressor stopped working. I unplugged it

NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.

Sounds like the cold control has stuck . Unplug the two wires from the cold control and plug them together. Turn one wire over and plug it into the other. away from the cold control.
The cold control is the knob in the ref that turns it on and off and has numbers on it. (Thermostat)
If it runs then that cold control (Thernostat) is the problem.
If that doesn't work DO THIS:
The relay on the compressor may need replaced
A relay starts the compressor with a higher voltage and then quickly kicks out
Thats what is happening with yours
Its best for a tech to replace The relay but you can do it
Take your model number to your Local Appliance parts store they will have a diagram
showing you how to install the relay. Its called a hard start relay
also try hooking the two wires together on the cold control to route around the cold control.

If you need more help GO HERE:

http://www.applianceaid.com/procedures.html

Thank you for using fixya
Leo Ponder
PLEASE VOTE FOR ME IF THIS WAS HELPFUL
9/20/2011 8:44:13 PM • VinoTemp VT-60... • Answered on Sep 20, 2011
0helpful
1answer

I need a new relay

Google part number 6R8MG. Should run around $20. I just bought one from APW.com Good Luck!
9/15/2011 11:44:47 PM • VinoTemp VT-60... • Answered on Sep 15, 2011
0helpful
1answer

Wine cooler making a squeaky

FREEZER FAN MOTOR MAY NEED REPLACED. THE EASIEST WAY IS TO TAKE OFF THE BACK PANEL IN FREEZER AND REMOVE THE FAN
MOTOR, TAKE IT TO THE NEAREST APPLIANCE PARTS STORE WITH YOUR MODEL NO.
EASY JOB.
I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically
If
you need more help go here:

http://www.applianceaid.com/procedures.html

MORE TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
9/7/2011 9:59:19 PM • VinoTemp VT-60... • Answered on Sep 07, 2011
0helpful
1answer

It stop working and there is a clicking noise in

first unplug unit for a few hours . remove back . under there there is a compressor and a fan plug in did the fan motor start itself ? if not touch blade a little , did it start now ? if so you have a bad fan motor ( real common with this cooler ) if the fan allways ran no problem you have a bad start relay on the compressor ( this is another real common problem ) you need to order a fan motor and or a start relay from vinotemp . on an order i made a week ago they had the motor but not the relay (relay kit ) it was on backorder , you may get lucky i just looked i do not have the phone #with me but you can fiind it on there website (thats where i found it ) good luck ps :on second thought dont play around , order the fan motor and the relay together no mater if the fan is working or not , even if it is it will not be for long Please if this answer helped , please rate this 3 or 4 stars . and keep me in the paid answer department . A 1 or 2 may knock me down into the unpaid ranks. Thanks Cactus Bob .
8/15/2011 11:09:34 PM • VinoTemp VT-60... • Answered on Aug 15, 2011
0helpful
1answer

The temperature was set in

This uses a temperature sensor and control board.

Vino temp @ 1-800-777-8466

The "clunk" noise sounds like the internal compressor motor mounts have broken.
3/23/2011 4:06:16 PM • VinoTemp VT-60... • Answered on Mar 23, 2011
Not finding what you are looking for?
VinoTemp VT-60 Wine Cooler Logo

55 questions posted

Ask a Question

Usually answered in minutes!

Top VinoTemp Refrigerators Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66847 Answers

Larry Ng
Larry Ng

Level 3 Expert

14563 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a VinoTemp Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

VinoTemp Refrigerators

  • VinoTemp Refrigerators

Most Popular Question

vt60 hold temperature in high 50s any