Top 20 GE Profile ASM10AA Air Conditioner Questions & Answers

0helpful
1answer

Hi my GE profile Air

Hi,

Here is a tip about troubleshooting your air conditioner...
There are many things that can cause your air conditioner not to cool...

Air Conditioner Trouble - Review the Possibilities

heatman101

aa
9/27/2010 5:51:10 AM • GE Profile... • 467 views • 0 helpful votes
0helpful
1answer

Compressor runs for short time

Hi,

Here is a tip about troubleshooting your air conditioner...
There are many things that can cause your air conditioner not to cool...

Air Conditioner Trouble - Review the Possibilities

heatman101
9/27/2010 4:56:53 PM • GE Profile... • 147 views • 0 helpful votes
0helpful
2answers

Unit will not turn on after power faiure. When

Depending on the age of the unit, you will find a reset button on the plug.
6/21/2010 2:24:10 PM • GE Profile... • 379 views • 0 helpful votes
0helpful
1answer

I have a sunbeam 12000 btu window unit air

Sounds like the switch is wired wrong.
When you put the switch on fan only the compressor should not run at all, therefore their shouldn't be any cold air.
Check the switch to see if it's wired right.
7/29/2009 8:53:02 PM • GE Profile... • 349 views • 0 helpful votes
0helpful
1answer

The unit is leaking water into the building. I

need to incline the unit so that it will drain out . Drop it down a bit from the back and it should be okay.
7/1/2009 10:06:41 PM • GE Profile... • 124 views • 0 helpful votes
0helpful
1answer

Fan speed problem on GE 12,000 BTU window unit

A multi-speed, remote controlled, fan controller that only allows one speed would require a very smart person to repair it. Even the technicians don't repair them. They just replace them. This is going to cost you some parts.
7/22/2008 1:14:53 PM • GE Profile... • 469 views • 0 helpful votes
0helpful
3answers

Air conditioner won' start

http://www.lowes.com/lowes/lkn?action=productDetail&productId=76034-1781-GET-213A&lpage=none Heres a link to a volt tester on Lowe's sight, use it or something similar to verify you have the correct voltage at your outlet (select the link by holding down lft mouse bttn and sliding curser to the end of address then rt click it and select copy hen rt click the fixy address up top and paste the new address in its place.-.fyi).
6/10/2008 9:02:30 AM • GE Profile... • 233 views • 0 helpful votes
1helpful
2answers

GE window air conditioner showing error code E8

Shery ck here... https://www.youtube.com/watch?v=K_WWBNEuSnU also clean the unit... unplug.. spray hose thru the vanes/coils outside/back side to remove dust and dirt from the unit. Let sit for 15-20 minutes before pluging back in. https://www.youtube.com/results?search_query=clean+window+ac+unit+without+removing Best to you.
7/19/2023 9:53:09 PM • GE Heating &... • 71 views • 1 helpful votes
0helpful
1answer

GE Profile gas cooktop knob/light issues

7/4/2023 8:03:04 PM • GE Heating &... • 37 views • 0 helpful votes
0helpful
1answer

GE SV850 range hood stopped working

Transformers do usually feel warm. If it is very hot it has likely failed internally. Check for output voltages with a digital multimeter.
7/1/2023 1:53:14 AM • GE Heating &... • 39 views • 0 helpful votes
0helpful
1answer

I have GE gas oven, getting error code F97

Impossible to say. There are a lot of variables here. Which country, and which model. Even different cities would charge different prices. It is a gas appliance, so you can't work on it yourself. Just for information, we are Fixya dot com, we aren't GE, we don't do pricing for them. The only way is to ask a local appliance shop. A good way is to ask for a recommendation on a local Facebook group where you live.
5/12/2023 11:09:29 PM • GE Heating &... • 38 views • 0 helpful votes
0helpful
1answer

I have a GE remote control universal remote and it is number 24922cl57252 and I want to pair that with my air conditioner which is a solace air portable air conditioner and heater how do I do it

Here are the steps to program your GE universal remote (model number 24922cl57252) to work with your Solace Air portable air conditioner:
  1. Turn on your Solace Air portable air conditioner.
  2. Press and hold the "Setup" button on your GE universal remote until the red indicator light stays on.
  3. Enter the code "991" using the number buttons on your GE remote. The red indicator light will turn off.
  4. Press the "Power" button on the GE remote.
  5. Press the "Up" or "Down" button to try and turn the air conditioner off. If the air conditioner turns off, press the "Setup" button to lock in the code.
If the air conditioner does not turn off, repeat steps 2-5 with a different code from the list below until the air conditioner turns off: Solace Air Portable Air Conditioner Codes: 0277, 0363, 0364, 0365, 0403, 0454, 0455, 0456, 0457, 0474, 0475, 0494, 0495, 0496, 0497 I hope this helps!
2/24/2023 10:14:25 PM • GE Heating &... • 90 views • 0 helpful votes
0helpful
1answer

PTAC Blows Cold Air in Heating Mode when it reaches -3F less than the Set Value on the Thermostat - Model: AZ65H15DABW6

It sounds like your PTAC (packaged terminal air conditioner) unit is malfunctioning. When the thermostat is set to heating mode, the PTAC should be blowing warm air, not cold air. There are a few possible causes for this issue:
  1. The PTAC may be low on refrigerant. If the unit is low on refrigerant, it may not be able to properly heat the air.
  2. The PTAC's reversing valve may be stuck in the cooling position. The reversing valve is responsible for switching the flow of refrigerant between heating and cooling mode. If it is stuck in the cooling position, the PTAC will blow cold air even when the thermostat is set to heating mode.
  3. The PTAC's heating element may be malfunctioning. If the heating element is not functioning properly, the PTAC will not be able to heat the air.
I recommend contacting a trained HVAC technician to diagnose and fix the issue with your PTAC. They will be able to determine the cause of the problem and repair it properly.
1/6/2023 4:56:02 PM • GE Heating &... • 250 views • 0 helpful votes
0helpful
1answer

PTAC fan stalls when heat pump stops

Sounds like a bad motor module.
12/10/2022 9:01:33 PM • GE Heating &... • 33 views • 0 helpful votes
0helpful
1answer

Why won't the heater of ge zoneline 2100 stay on

Hi, If the heater goes off right away when you start it, please check the corresponding fuse within your fusebox. Also, checking for any warn wires would be good as well. I would also test other outlets verify that it's not your current power source that's the issue. Thank you.
11/2/2022 7:36:04 AM • GE Heating &... • 34 views • 0 helpful votes
0helpful
1answer

What does a code E4 mean on my GE window air unit?

https://www.reviewhomewarranties.com/home-maintenance/hvac/fixing-e4-error-on-air-conditioner/
7/30/2022 5:01:42 AM • GE Heating &... • 79 views • 0 helpful votes
0helpful
2answers

Why will my GE Zoneline 2100 work on high cool and high heat settings, but on low cool and low heat the fan won't run.

I don’t believe the remote tstat accepts those functions to change the fan speed versus using the on board controls. Try to change the fan speed while using the on board controls and when you have that setup then go back and change it to remote tstat setting.
7/4/2022 7:32:18 PM • GE Heating &... • 76 views • 0 helpful votes
1helpful
1answer

GE air conditioner jumps to 86 on the display

bad temp sensor
5/16/2022 10:42:37 PM • GE Heating &... • 279 views • 1 helpful votes
Not finding what you are looking for?
GE Profile ASM10AA Air Conditioner Logo

15 questions posted

Ask a Question

Usually answered in minutes!

Top GE Heating & Cooling Experts

Brad Brown

Level 3 Expert

19187 Answers

vince

Level 3 Expert

2530 Answers

Alfredo Texmenistan

Level 1 Expert

26 Answers

Are you a GE Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

GE Heating & Cooling

  • GE Heating & Cooling

Most Popular Question

compressor runs short time

  • Heating & Cooling
Loading...