Please help,if my board use in far away gig then it always shake cause by vehicle and rough road.. is it possible that the IC on my board may be affected? what part of my keyboard will be affected...
There are numerous ICs, as well as other components and connections, that may have been affected by rough handling, shaking, bumping and banging of the keyboard.
As the other person stated, if it’s still under warranty, take it to the appropriate repair person.
If it's not covered and you lack experience in similar repairs, take it to a qualified tech.
If you are inclined to do this yourself; There are a multitude of DIFFERENT SIZE screws that you must remove to open the keyboard. PAY CLOSE ATTENTION to which goes where. Take pictures and make notes. And BE VERY CAREFUL OPENING THE CASE. If I remember correctly, there a couple of short cables connecting the top and bottom halves. Proceed slowly.
You should be able to, at the very least, do a visual inspection yourself. Look for loose cable connections and dislocated components. More than likely, that is the cause of your problem. If plugging something back in doesn't remedy, and you are inexperienced, take it to a qualified tech.
If and when you fix the instrument, I suggest that you transport the keyboard in a well-padded flight case. Good luck.
Korg X50 synth keybd -
Hello,
To gain access to the electronics, you need to take the Korg X50 synth keyboard apart. And to take the keyboard apart, you must unscrew all the screws including the one with a dash mark and the ones with dot.
All screws must be unscrewed in other to successfully take the keyboard cover apart.
Once you have successfully remove all the screws, you can use a flat screw driver to pry the keyboard from the side applying little force.
But I would advice that if this keyboard is till under warranty, I would suggest, you take it back to where you bought it so that another one will be give to you. The moment the keyboard is taken apart or disassembled, the warranty of the keyboard would be void. I hope you are aware of this.
Good luck.
When turning on my Korg
Sounds like it's probably the connections. Yes, contacting the company is the very best thing to do! :) Smart person!:)
The jack end of the ac adapter (plug into the
The jack has probably been ripped loose from the circuit board by repeated use over time. The jack must be de-soldered, then epoxy glued to the circuit board. Once the glue sets, the original connections need to be replaced with short sections of wire to bridge the broken portions of printed circuit. A relatively simple repair if done carefully. Hope this helps!
When replaceing battery in 01R/W when module should be connected to power again - before or after battery replacment ?
When replacing the battery on a 1R/w module, it is generally recommended to disconnect the module from power before replacing the battery. This is to prevent any potential damage or issues that may occur from power being applied to the module during the battery replacement process.
Once the battery has been replaced, it is recommended to reconnect the module to power and perform a power-on self-test (POST) to ensure that the module is functioning properly and that the battery replacement was successful.
It is also important to check the manufacturer's instructions for the specific 1R/w module you are working with, as there may be additional steps or precautions that need to be taken. It's important to follow the manufacturer's instructions in order to avoid any damage to the equipment or to ensure proper operation of the module.